CHROMIUM VI COMPOUNDS (HEXAVALENT CHROMIUM)‡

Chemical Identification

CAS # 18540-29-9 (Cr VI), 7788-98-9, 7789-09-5, 12231-18-4, 12000-34-9, 10294-40-3, 54692-53-4, 1344-38-3, 13765-19-0, 14986-48-2, 12324-08-2, 12324-05-9, 14977-61-8, 8049-64-7, 7758-97-6, 1344-37-2, 7789-00-6, 7778-50-9, 7775-11-3, 12018-32-5, 10588-01-9, 7789-06-2, 54322-60-0, 12656-85-8, 14675-41-3, 13530-65-9, 1328-67-2, 1308-13-0, 66516-58-3, 15930-94-6, 12206-12-1, 37809-34-0, 12527-08-1, 11103-86-9
Formula

various

Synonyms

chromic anhydride, chromic oxide, chromium(VI) oxide (1:3), chromium trioxide, ammonium chromate, ammonium dichromate, barium chromate, basic lead chromate, calcium chromate, chromium [VI] chloride, chromium trioxide, chromyl chloride, lead chromate, potassium chromate, potassium dichromate, sodium chromate, sodium dichromate, strontium chromate, molybdenum orange, zinc chromate, zinc chromate hydroxides, zinc potassium chromates (hydroxides)

Physical Properties

Physical description Very hard gray solid with a metallic luster.
Boiling point Molecular weight
Freezing point/melting point Vapor pressure
Flash point Vapor density
Specific gravity Ionization potential
Lower explosive limit (LEL) Upper explosive limit (UEL)
NFPA health rating NFPA fire rating
NFPA reactivity rating NFPA special instruction
Vapor hazard ratio (VHR)
Historical exceedance percentage
Target organs

Monitoring Methods Used by OSHA

Analyte code (IMIS no.) 0689 0689 - WIPE
Sampling group
Sampler/Sampling media For Welding and Painting Operations use Hexavalent Chromium Filters and Cassettes (37 mm PVC) [SLTC104] or (25 mm PVC) [SLTC105] [SLTC104]; For Plating Operations use 37 mm Quartz Fiber Filter coated with 1% NaOH [SLTC106] [SLTC106] Hexavalent Chromium Filters (For Wipe Samples Only) [SLTC107]
Sampling time*

480 min

Sampling volume (TWA)*

960 L

Sampling flow rate (TWA)*

2 L/min

Sampling volume (STEL/Peak/C)*
Sampling flow rate (STEL/Peak/C)*
Analytical method instruments IC IC-UV
Method reference OSHA ID-215v.2 (fully validated) OSHA W4001 (fully validated)
Notes

All samples taken for CHROMIUM VI COMPOUNDS should be shipped to the OSHA SLTC within 24 hours after sampling by overnight delivery for stabilization and analysis.

All samples taken for CHROMIUM VI COMPOUNDS should be shipped to the OSHA SLTC within 24 hours after sampling by overnight delivery for stabilization and analysis.

Special requirements

* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.

Bulk/Wipe Method

Wipe Sampler/Sampling media

See the "Monitoring Methods Used by OSHA" section above for details.

Bulk Method

Available

On-Site Screening Techniques

Device
Model/Type
Sampling information
(see manufacturer instructions)

Exposure Limits

OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
NIOSH REL
Up to 10-hour TWA
(ST) STEL
(C) Ceiling
ACGIH TLV©
8-hour TWA
(ST) STEL
(C) Ceiling
CAL/OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
PEL-TWA

5 µg/m³ [2.5 µg/m³ Action Level]

REL-TWA

0.0002 mg/m³ (8 hr TWA)

TLV-TWA

0.0002 mg/m³ (inhalable particulate matter) [2017]

PEL-TWA

0.005 mg/m³

PEL-STEL REL-STEL TLV-STEL

0.0005 mg/m³ (inhalable particulate matter) [2017]

PEL-STEL
PEL-C REL-C TLV-C PEL-C

0.1 mg/m³

Skin notation

N

Skin notation

N

Skin notation

N

Skin notation

N

Notes:

OSHA's Chromium (VI) standard applies to occupational exposures to any chromium species with a valence of positive six, regardless of form or compound. See 29 CFR 1910.1026 Chromium (VI). See 29 CFR 1910.1000 Table Z-1 and/or 29 CFR 1910.1000 Table Z-2for any operations or sectors where the exposure limits in §1910.1026 are stayed or otherwise not in effect.

Notes:

CARCINOGEN (Ca): REDUCE EXPOSURE TO LOWEST FEASIBLE CONCENTRATION. See Appendix A, NIOSH Potential Occupational Carcinogens and Appendix C, Supplementary Exposure Limits.

Notes:

Skin, dermal sensitization (DSEN) and respiratory sensitization (RSEN) (for water-soluble compounds)

Notes:
Health factors:  See NIH-NLM PubChem. IDLH
Carcinogenic classifications: EPA-A; K; D; CBD, IARC-1, NIOSH-Ca, NTP-K, TLV-A1 Notes:

Ca

AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:

Additional Resources and Literature References

Last Updated Date : 11/21/2022

CHROMIUM(III) COMPOUNDS (as Cr)†

Chemical Identification

CAS # 7440-47-3
Formula

Cr

Synonyms

Synonyms vary depending upon the specific Chromium(III) compound. [Note: Chromium(III) compounds include soluble chromic salts.]

Physical Properties

Physical description Appearance and odor vary depending upon the specific compound.
Boiling point 4788°F Molecular weight 52
Freezing point/melting point 3452°F Vapor pressure depends upon the specific compound
Flash point Vapor density
Specific gravity 7.2 Ionization potential
Lower explosive limit (LEL) Upper explosive limit (UEL)
NFPA health rating NFPA fire rating
NFPA reactivity rating NFPA special instruction
Vapor hazard ratio (VHR)
Historical exceedance percentage
Target organs

Monitoring Methods Used by OSHA

Analyte code (IMIS no.)
Sampling group
Sampler/Sampling media
Sampling time*
Sampling volume (TWA)*
Sampling flow rate (TWA)*
Sampling volume (STEL/Peak/C)*
Sampling flow rate (STEL/Peak/C)*
Analytical method instruments
Method reference
Notes

See CHROMIUM, METAL & INSOLUBLE SALTS

Special requirements

* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.

Bulk/Wipe Method

Wipe Sampler/Sampling media
Bulk Method

On-Site Screening Techniques

Device
Model/Type
Sampling information
(see manufacturer instructions)

Exposure Limits

OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
NIOSH REL
Up to 10-hour TWA
(ST) STEL
(C) Ceiling
ACGIH TLV©
8-hour TWA
(ST) STEL
(C) Ceiling
CAL/OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
PEL-TWA

0.5 mg/m³

REL-TWA

0.5 mg/m³

TLV-TWA

0.003 mg/m³ (inhalable particulate matter) [2017]

PEL-TWA

0.5 mg/m³

PEL-STEL REL-STEL TLV-STEL PEL-STEL
PEL-C REL-C TLV-C PEL-C
Skin notation

N

Skin notation

N

Skin notation

N

Skin notation

N

Notes:

See 29 CFR 1910.1000 Table Z-1.

Notes:

See Appendix C, Supplementary Exposure Limits. [Chromic Acid and Chromates (as CrO₃), Chromium(II) and Chromium(III) Compounds (as Cr), and Chromium Metal (as Cr)]

Notes:

dermal senstization (DSEN), respiratory sensitization (RSEN) (for water-soluble compounds)

Notes:
Health factors:  See NIH-NLM PubChem. IDLH

250 mg/m³

Carcinogenic classifications: EPA-D; TLV-A4; IARC-3 Notes:

as Cr

AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:

Additional Resources and Literature References

Last Updated Date : 01/29/2021

CHROMIUM(II) COMPOUNDS (as Cr)†

Chemical Identification

CAS # 7440-47-3
Formula

Cr

Synonyms

Synonyms vary depending upon the specific Chromium(II) compound. [Note: Chromium(II) compounds include soluble chromous salts.]

Physical Properties

Physical description Appearance and odor vary depending upon the specific compound.
Boiling point 4788°F Molecular weight 52
Freezing point/melting point 3452°F Vapor pressure depends upon the specific compound
Flash point Vapor density
Specific gravity 7.2 Ionization potential
Lower explosive limit (LEL) Upper explosive limit (UEL)
NFPA health rating NFPA fire rating
NFPA reactivity rating NFPA special instruction
Vapor hazard ratio (VHR)
Historical exceedance percentage
Target organs

Monitoring Methods Used by OSHA

Analyte code (IMIS no.)
Sampling group
Sampler/Sampling media
Sampling time*
Sampling volume (TWA)*
Sampling flow rate (TWA)*
Sampling volume (STEL/Peak/C)*
Sampling flow rate (STEL/Peak/C)*
Analytical method instruments
Method reference
Notes

See CHROMIUM, METAL & INSOLUBLE SALTS

Special requirements

* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.

Bulk/Wipe Method

Wipe Sampler/Sampling media
Bulk Method

On-Site Screening Techniques

Device
Model/Type
Sampling information
(see manufacturer instructions)

Exposure Limits

OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
NIOSH REL
Up to 10-hour TWA
(ST) STEL
(C) Ceiling
ACGIH TLV©
8-hour TWA
(ST) STEL
(C) Ceiling
CAL/OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
PEL-TWA

0.5 mg/m³

REL-TWA

0.5 mg/m³

TLV-TWA

0.5 mg/m³ (inhalable particulate matter) [2017]

PEL-TWA

0.5 mg/m³

PEL-STEL REL-STEL TLV-STEL PEL-STEL
PEL-C REL-C TLV-C PEL-C
Skin notation

N

Skin notation

N

Skin notation

N

Skin notation

N

Notes:

See 29 CFR 1910.1000 Table Z-1.

Notes:

See Appendix C, Supplementary Exposure Limits. [Chromic Acid and Chromates (as CrO₃), Chromium(II) and Chromium(III) Compounds (as Cr), and Chromium Metal (as Cr)]

Notes: Notes:
Health factors:  See NIH-NLM PubChem. IDLH

250 mg/m³

Carcinogenic classifications: EPA-D; IARC-3 Notes:

as Cr

AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:

Additional Resources and Literature References

Last Updated Date : 06/26/2023

CHROMIUM, METAL & INSOLUBLE SALTS (as Cr)†

Chemical Identification

CAS # 7440-47-3
Formula

Cr

Synonyms

chrome; chromium

Physical Properties

Physical description Blue-white to steel-gray, lustrous, brittle, hard, odorless solid.
Boiling point 4788°F Molecular weight 52
Freezing point/melting point 3452°F Vapor pressure 0 mmHg (approx)
Flash point Vapor density
Specific gravity 7.14 Ionization potential
Lower explosive limit (LEL) Upper explosive limit (UEL)
NFPA health rating NFPA fire rating
NFPA reactivity rating NFPA special instruction
Vapor hazard ratio (VHR)
Historical exceedance percentage
Target organs

Monitoring Methods Used by OSHA

Analyte code (IMIS no.) 0685
Sampling group METALSSG-2
Sampler/Sampling media Pre-assembled cassette with mixed cellulose ester filter (MCEF) 0.8 micron (25 or 37 mm) [MAWP025A0 or MAWP037A0]
Sampling time*

240-480 min

Sampling volume (TWA)*

480-960 L

Sampling flow rate (TWA)*

2 L/min

Sampling volume (STEL/Peak/C)*
Sampling flow rate (STEL/Peak/C)*
Analytical method instruments ICP
Method reference OSHA ID-125G (fully validated)
Notes

Results are provided for the presence and amount or concentration of a specific element or elements.

The stated identity of the actual sample contents (such as specific form, valence state, or compound) is based on the assumption that the material sampled is as identified by the compliance officer using available documentation of materials and processes. Smaller filters recommended for sampling inside welding hoods.

Special requirements

For the entire suite of analytes listed in METALSSG-2, request analyte code 2587.

* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.

Bulk/Wipe Method

Wipe Sampler/Sampling media

Ghost Wipe [SKC 225-2414]

Bulk Method

Available

On-Site Screening Techniques

Device
Model/Type
Sampling information
(see manufacturer instructions)

Exposure Limits

OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
NIOSH REL
Up to 10-hour TWA
(ST) STEL
(C) Ceiling
ACGIH TLV©
8-hour TWA
(ST) STEL
(C) Ceiling
CAL/OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
PEL-TWA

1 mg/m³

REL-TWA

0.5 mg/m³

TLV-TWA

0.5 mg/m³ (inhalable particulate matter) [2017]

PEL-TWA

0.5 mg/m³

PEL-STEL REL-STEL TLV-STEL PEL-STEL
PEL-C REL-C TLV-C PEL-C
Skin notation

N

Skin notation

N

Skin notation

N

Skin notation

N

Notes:

See 29 CFR 1910.1000 Table Z-1.

Notes: Notes: Notes:
Health factors:  See NIH-NLM PubChem. IDLH

250 mg/m³

Carcinogenic classifications: IARC-3, EPA-A; K; D; CBD Notes:
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:

Additional Resources and Literature References

Last Updated Date : 12/21/2020

GRAPHITE (SYNTHETIC)†

Chemical Identification

CAS # 7440-44-0
Formula
 

C

Synonyms
 

activated carbon [Note: Also see specific listing for Graphite (natural).]

Physical Properties

Physical description Black grains that have been treated to improve absorptive ability.
Boiling point Molecular weight
Freezing point/melting point Vapor pressure 0 mmHg (approx)
Flash point Vapor density
Specific gravity Ionization potential
Lower explosive limit (LEL) Upper explosive limit (UEL)
NFPA health rating NFPA fire rating
NFPA reactivity rating NFPA special instruction
Vapor hazard ratio (VHR)
Historical exceedance percentage
Target organs

Monitoring Methods Used by OSHA

Analyte code (IMIS no.) 1366 (total); request using analyte code 9135 G100 (resp); request using analyte code 9130
Sampling group
Sampler/Sampling media Tared low-ash 37 mm PVC filter, 5 microns [SLTC108] Tared Low-Ash 37 mm PVC Filter, 5 microns in 3-piece cassette with a Lumsden-Lynch vertical elutriator [SLTC114]
Sampling time*
 

240-480 min

 

240-480 min

Sampling volume (TWA)*
 

960 L

 

816 L

Sampling flow rate (TWA)*
 

2 L/min

 

1.7 L/min ±5%

Sampling volume (STEL/Peak/C)*
 

 

 

 

Sampling flow rate (STEL/Peak/C)*
 

 

 

 

Analytical method instruments Gravimetric Gravimetric
Method reference OSHA PV2121 (partially validated) OSHA PV2121 (partially validated)
Notes
 

If the net weight of the sample yields a concentration below the PEL after considering the associated SAE , the SLTC will perform no further work on the sample and the sample air concentration will be reported as the calculated gravimetric air concentration.

If the net weight corresponds to an amount greater than the PEL value after considering the associated SAE, the sample may be analyzed for  the applicable component and appropriate results will be reported.

 

If the filter is not overloaded, samples can be collected up to an 8-hour period. If the net weight of the sample yields a concentration below the PEL after considering the associated SAE , the SLTC will perform no further work on the sample and the sample air concentration will be reported as the calculated gravimetric air concentration.

If the net weight corresponds to an amount greater than the PEL value after considering the associated SAE, the sample may be analyzed for  the applicable component and appropriate results will be reported.

Special requirements
 

FOR TOTAL DUST SAMPLES, DO NOT USE A CYCLONE!!

 

 

* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.

Bulk/Wipe Method

Wipe Sampler/Sampling media
 

 

Bulk Method
 

 

On-Site Screening Techniques

Device
Model/Type
Sampling information
(see manufacturer instructions)

Exposure Limits

OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
NIOSH REL
Up to 10-hour TWA
(ST) STEL
(C) Ceiling
ACGIH TLV©
8-hour TWA
(ST) STEL
(C) Ceiling
CAL/OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
PEL-TWA
 

15 mg/m³ (total dust), 5 mg/m³ (respirable fraction)

REL-TWA
 

 

TLV-TWA
 

2 mg/m³ (respirable particulate matter) [1988]

PEL-TWA
 

10 mg/m³ (total dust), 5 mg/m³ (respirable fraction)

PEL-STEL
 

 

REL-STEL
 

 

TLV-STEL
 

 

PEL-STEL
 

 

PEL-C
 

 

REL-C
 

 

TLV-C
 

 

PEL-C
 

 

Skin notation
 

N

Skin notation
 

N

Skin notation
 

N

Skin notation
 

N

Notes:
 

See 29 CFR 1910.1000 Table Z-1.

Notes:
 

See Appendix D - Substances with No Established RELs.

Notes:
 

 

Notes:
 

See footnote [n].

Health factors:  See NIH-NLM PubChem. IDLH
Carcinogenic classifications: Not listed Notes:
 

 

AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:
 

 

Additional Resources and Literature References

Last Updated Date : 01/29/2021

CADMIUM‡

Chemical Identification

CAS # 7440-43-9 (elemental)
Formula

Cd

Synonyms

cadmium metal; synonyms vary depending upon the specific cadmium compound.

Physical Properties

Physical description Silver-white, blue-tinged lustrous, odorless solid.
Boiling point 1409°F Molecular weight 112.4
Freezing point/melting point 610°F Vapor pressure 0 mmHg (approx)
Flash point Vapor density
Specific gravity 8.65 (metal) Ionization potential
Lower explosive limit (LEL) Upper explosive limit (UEL)
NFPA health rating NFPA fire rating
NFPA reactivity rating NFPA special instruction
Vapor hazard ratio (VHR)
Historical exceedance percentage
Target organs

Monitoring Methods Used by OSHA

Analyte code (IMIS no.) C141 (high sensitivity) C141 C141
Sampling group METALSSG-1 METALSSG-2 METALSSG-3
Sampler/Sampling media Mixed cellulose ester filter (MCEF) 0.8 micron (37 mm) and filter spacer with Na₂CO₃ impregnated backup pad, in a 3-piece cassette [SKC 225-9001] Pre-assembled cassette with mixed cellulose ester filter (MCEF) 0.8 micron (25 or 37 mm) [MAWP025A0 or MAWP037A0] Mixed cellulose ester filter (MCEF) 0.8 micron (37 mm) and filter spacer with Na₂CO₃ impregnated backup pad, in a 3-piece cassette [SKC 225-9001]
Sampling time*

240-480 min

240-480 min

240-480 min

Sampling volume (TWA)*

480-960 L

480-960 L

480-960 L

Sampling flow rate (TWA)*

2 L/min

2 L/min

2 L/min

Sampling volume (STEL/Peak/C)*

30 L

30 L

Sampling flow rate (STEL/Peak/C)*

2 L/min

2 L/min

Analytical method instruments ICP-MS ICP ICP-MS
Method reference OSHA 5003 (fully validated) OSHA ID-125G (fully validated) OSHA ID-206 (fully validated)
Notes

The METALSSG-1 sampling group members are analyzed using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) to target the expanded standards metals As, Cd, and Pb with high sensitivity (clean samples and smear tabs only).

If cadmium is the only analyte of interest, use the single analyte code C141. If the filter is not overloaded, samples may be collected up to an 8-hour period. If As, Cd, Cu, Fe, or Zn are detected, results will be provided.

Results are provided for the presence and amount or concentration of a specific element or elements. The stated identity of the actual sample contents (such as specific form, valence state, or compound) is based on the assumption that the material sampled is as identified by the compliance officer using available documentation of materials and processes. Smaller filters recommended for sampling inside welding hoods.

If the filter is not overloaded, samples may be collected up to an 8-hour period. Results are provided for the presence and amount or concentration of a specific element or elements. The stated identity of the actual sample contents (such as a specific form or compound) is based on the assumption that the material sampled is as identified by the compliance officer using available documentation of materials and processes. The physical form of a sample (dust, mist, or fume) is identified by the compliance officer using available documentation of materials and processes.

Special requirements

For high sensitivity, request any or all of analytes listed in METALSSG-1 (0260, C141, & 1591).

For the entire suite of analytes listed in METALSSG-2, request analyte code 2587.

For the entire suite of analytes listed in METALSSG-3, which may be found during soldering and brazing operations, request analyte code S131.

* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.

Bulk/Wipe Method

Wipe Sampler/Sampling media

See sampling group information for media.

Bulk Method

Available

On-Site Screening Techniques

Device
Model/Type
Sampling information
(see manufacturer instructions)

Exposure Limits

OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
NIOSH REL
Up to 10-hour TWA
(ST) STEL
(C) Ceiling
ACGIH TLV©
8-hour TWA
(ST) STEL
(C) Ceiling
CAL/OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
PEL-TWA

5 µg/m³ [2.5 µg/m³ Action Level]

REL-TWA TLV-TWA PEL-TWA

0.005 mg/m³

PEL-STEL REL-STEL TLV-STEL PEL-STEL
PEL-C REL-C TLV-C PEL-C
Skin notation

N

Skin notation

N

Skin notation

N

Skin notation

N

Notes:

See 29 CFR 1910.1027 and 29 CFR 1926.1127 (Construction) for additional information. The PELs listed in 29 CFR 1910.1000 Table Z-2 for cadmium fume and cadmium dust apply to any operations or sectors for which the Cadmium standard, CFR 1910.1027, is stayed or otherwise not in effect.

Notes:

CARCINOGEN (Ca): REDUCE EXPOSURE TO LOWEST FEASIBLE CONCENTRATION (LOQ 0.1 mg/m³). See Appendix A, NIOSH Potential Occupational Carcinogens

Notes:

Visit the ACGIH TLV site for specific data
BEI®

Notes:
Health factors:  See NIH-NLM PubChem. IDLH

9 mg/m³

Carcinogenic classifications: IARC-1, NIOSH-Ca, NTP-K, OSHA-Ca, TLV-A2, EPA-B1 Notes:

Ca

AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:

Additional Resources and Literature References

Last Updated Date : 04/08/2024

BERYLLIUM & COMPOUNDS (as Be)‡

Chemical Identification

CAS # 7440-41-7
Formula

Be

Synonyms

Synonyms vary depending upon the specific beryllium compound.

Physical Properties

Physical description hard, brittle, gray-white solid, metal
Boiling point 4532°F Molecular weight 9.0
Freezing point/melting point 2349°F Vapor pressure 0 mmHg (approx)
Flash point Vapor density
Specific gravity 1.85 (metal) Ionization potential
Lower explosive limit (LEL) Upper explosive limit (UEL) 2349°F
NFPA health rating 3 NFPA fire rating 1
NFPA reactivity rating 0 NFPA special instruction
Vapor hazard ratio (VHR)
Historical exceedance percentage
Target organs

Monitoring Methods Used by OSHA

Analyte code (IMIS no.) 0365 (high sensitivity)
Sampling group
Sampler/Sampling media Pre-assembled cassette with mixed cellulose ester filter (MCEF) 0.8 micron (37 mm) [MAWP037A0]
Sampling time*

240 min

Sampling volume (TWA)*

480 L

Sampling flow rate (TWA)*

2 L/min

Sampling volume (STEL/Peak/C)*

30 L

Sampling flow rate (STEL/Peak/C)*

2 L/min

Analytical method instruments ICP-AES
Method reference OSHA 1023 (fully validated)
Notes

Results are provided for the presence and amount or concentration of a specific element or elements.

The stated identity of the actual sample contents (such as specific form, valence state, or compound) is based on the assumption that the material sampled is as identified by the compliance officer using available documentation of materials and processes.

Special requirements

* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.

Bulk/Wipe Method

Wipe Sampler/Sampling media

Wipe with Whatman smear tab. [WHA1450993]

Bulk Method

Available

On-Site Screening Techniques

Device
Model/Type
Sampling information
(see manufacturer instructions)

Exposure Limits

OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
NIOSH REL
Up to 10-hour TWA
(ST) STEL
(C) Ceiling
ACGIH TLV©
8-hour TWA
(ST) STEL
(C) Ceiling
CAL/OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
PEL-TWA

0.2 µg/m³ [0.1 µg/m³ Action Level]

REL-TWA TLV-TWA PEL-TWA

0.0002 mg/m³

PEL-STEL

2 µg/m³

REL-STEL TLV-STEL PEL-STEL

0.002 mg/m³

PEL-C REL-C TLV-C PEL-C

0.025 mg/m³

Skin notation

N

Skin notation

N

Skin notation

Y

Skin notation

N

Notes:

See 29 CFR 1910.1024, Beryllium. See 29 CFR 1910.1000 Table Z-2for any operations or sectors where the exposure limits in 1910.1024 are stayed or otherwise not in effect.

Notes:

CARCINOGEN (Ca): REDUCE EXPOSURE TO LOWEST FEASIBLE CONCENTRATION. See Appendix A, NIOSH Potential Occupational Carcinogens

Notes:

Visit the ACGIH TLV site for specific data
skin, dermal sensitizer (DSEN) (soluble compounds), respiratory sensitizer (RSEN) (soluble and insoluble compounds)

Notes:

See also California Code of Regulations, Title 8 §1535.1 Beryllium., §5205. Beryllium., and §8359.1 Beryllium.

Health factors:  See NIH-NLM PubChem. IDLH

4 mg/m³

Carcinogenic classifications: IARC-1, NIOSH-Ca, NTP-K, TLV-A1, EPA-B1; L; CBD Notes:

Ca

AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:

--/0.025 mg/m³/0.1 mg/m³

Additional Resources and Literature References

Last Updated Date : 03/27/2024

BARIUM, SOLUBLE COMPOUNDS (EXCEPT BARIUM SULFATE)†

Chemical Identification

CAS # 7440-39-3
Formula

Ba

Synonyms

Synonyms vary depending upon the specific soluble barium compound.

Physical Properties

Physical description A silver to white metallic, odorless solid
Boiling point 2984°F Molecular weight 137.33
Freezing point/melting point 1337°F Vapor pressure 10 mmHg at 1920°F
Flash point Vapor density
Specific gravity 3.51 at 68°F Ionization potential
Lower explosive limit (LEL) Upper explosive limit (UEL)
NFPA health rating NFPA fire rating
NFPA reactivity rating NFPA special instruction
Vapor hazard ratio (VHR)
Historical exceedance percentage
Target organs

Monitoring Methods Used by OSHA

Analyte code (IMIS no.) 0310
Sampling group
Sampler/Sampling media Tared low-ash 37 mm PVC filter, 5 microns [SLTC108]
Sampling time*

240-480 min

Sampling volume (TWA)*

480-960 L

Sampling flow rate (TWA)*

2 L/min

Sampling volume (STEL/Peak/C)*
Sampling flow rate (STEL/Peak/C)*
Analytical method instruments Gravimetric
Method reference OSHA PV2121 (partially validated)
Notes

Samples are first analyzed gravimetrically. If the gravimetric result of a sample yields a concentration below the permissible exposure limit (PEL), the SLTC will report the calculated air concentration from the gravimetric result, qualified as less than or equal to the gravimetric result; no further work on the sample will be performed.

If the gravimetric result indicates an air concentration greater than the PEL, the sample will proceed for elemental analysis. Results will be reported from the elemental analysis for the element only; the stated identity of the actual sample contents is based on the assumption that the material sampled is as identified by the compliance officer using available documentation of materials and processes.

Analysis for this analyte is based on water solubility.

Special requirements

FOR TOTAL DUST SAMPLES, DO NOT USE A CYCLONE!!

* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.

Bulk/Wipe Method

Wipe Sampler/Sampling media

Wipe with Whatman smear tab. [WHA1450993]

Bulk Method

On-Site Screening Techniques

Device
Model/Type
Sampling information
(see manufacturer instructions)

Exposure Limits

OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
NIOSH REL
Up to 10-hour TWA
(ST) STEL
(C) Ceiling
ACGIH TLV©
8-hour TWA
(ST) STEL
(C) Ceiling
CAL/OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
PEL-TWA

0.5 mg/m³

REL-TWA

0.5 mg/m³

TLV-TWA PEL-TWA

0.5 mg/m³

PEL-STEL REL-STEL TLV-STEL PEL-STEL
PEL-C REL-C TLV-C PEL-C
Skin notation

N

Skin notation

N

Skin notation

NA

Skin notation

NA

Notes:

See 29 CFR 1910.1000 Table Z-1.

Notes: Notes:

Visit the ACGIH TLV site for specific data

Notes:
Health factors:  See NIH-NLM PubChem. IDLH

1100 mg Ba/m³ 

Carcinogenic classifications: EPA-CBD; NL; D, TLV-A4 Notes:
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:

Additional Resources and Literature References

Last Updated Date : 04/02/2024

ARSENIC, ORGANIC COMPOUNDS †

Chemical Identification

CAS # 7440-38-2
Formula

As

Synonyms

Synonyms vary depending upon the specific organic arsenic compound.

Physical Properties

Physical description Varies with specific organic arsenic compound.
Boiling point Molecular weight
Freezing point/melting point Vapor pressure depends upon the specific compound
Flash point Vapor density
Specific gravity Ionization potential
Lower explosive limit (LEL) Upper explosive limit (UEL)
NFPA health rating NFPA fire rating
NFPA reactivity rating NFPA special instruction
Vapor hazard ratio (VHR)
Historical exceedance percentage
Target organs

Monitoring Methods Used by OSHA

Analyte code (IMIS no.) A202
Sampling group
Sampler/Sampling media
Sampling time*
Sampling volume (TWA)*
Sampling flow rate (TWA)*
Sampling volume (STEL/Peak/C)*
Sampling flow rate (STEL/Peak/C)*
Analytical method instruments
Method reference
Notes

Call the SLTC before sampling. Specialized equipment required for analysis of these samples cited in NIOSH Method 5022 is presently not available at the SLTC.

Special requirements

* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.

Bulk/Wipe Method

Wipe Sampler/Sampling media
Bulk Method

On-Site Screening Techniques

Device
Model/Type
Sampling information
(see manufacturer instructions)

Exposure Limits

OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
NIOSH REL
Up to 10-hour TWA
(ST) STEL
(C) Ceiling
ACGIH TLV©
8-hour TWA
(ST) STEL
(C) Ceiling
CAL/OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
PEL-TWA

0.5 mg/m³

REL-TWA TLV-TWA PEL-TWA

0.2 mg/m³

PEL-STEL REL-STEL TLV-STEL PEL-STEL
PEL-C REL-C TLV-C PEL-C
Skin notation

N

Skin notation

N

Skin notation

NA

Skin notation

N

Notes:

See 29 CFR 1910.1000 Table Z-1.

Notes:

Not established

Notes:

Not established

Notes:
Health factors:  See NIH-NLM PubChem. IDLH
Carcinogenic classifications: Not listed Notes:
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:

Additional Resources and Literature References

Last Updated Date : 01/29/2021

ARSENIC, INORGANIC COMPOUNDS (as As)‡

Chemical Identification

CAS # 7440-38-2
Formula

As

Synonyms

arsenic metal; arsenia; others vary depending upon the specific arsenic compound.

Physical Properties

Physical description Silver-gray or tin-white metal, brittle odorless solid.
Boiling point 1135°F (sublimes) Molecular weight 74.92
Freezing point/melting point 1135°F (sublimes) Vapor pressure 0 mmHg (approx)
Flash point Vapor density
Specific gravity 5.73 (metal) Ionization potential
Lower explosive limit (LEL) Upper explosive limit (UEL)
NFPA health rating 3 NFPA fire rating 2
NFPA reactivity rating 0 NFPA special instruction
Vapor hazard ratio (VHR)
Historical exceedance percentage
Target organs

Monitoring Methods Used by OSHA

Analyte code (IMIS no.) 0260 (high sensitivity)
Sampling group METALSSG-1
Sampler/Sampling media Mixed cellulose ester filter (MCEF) 0.8 micron (37 mm) and filter spacer with Na₂CO₃ impregnated backup pad, in a 3-piece cassette [SKC 225-9001]
Sampling time*

240-480 min
 

Sampling volume (TWA)*

480-960 L

Sampling flow rate (TWA)*

2 L/min

Sampling volume (STEL/Peak/C)*
Sampling flow rate (STEL/Peak/C)*
Analytical method instruments ICP
Method reference OSHA 5003 (fully validated)
Notes

The METALSSG-1 sampling group members are analyzed using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) to target the expanded standards metals As, Cd, and Pb with high sensitivity (clean samples and smear tabs only).

If arsenic is the only analyte of interest, use the single analyte code 0260. If the filter is not overloaded, samples may be collected up to an 8-hour period. If As, Cd, Cu, Fe, Pb or Zn are detected, results will be provided.

Special requirements

For volatile arsenic compounds, a sodium carbonate-impregnated BUP is required in conjunction with the MCE filter [225-9001].

* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.

Bulk/Wipe Method

Wipe Sampler/Sampling media

Wipe with Whatman smear tab. [WHA1450993]

Bulk Method

Available

On-Site Screening Techniques

Device
Model/Type
Sampling information
(see manufacturer instructions)

Exposure Limits

OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
NIOSH REL
Up to 10-hour TWA
(ST) STEL
(C) Ceiling
ACGIH TLV©
8-hour TWA
(ST) STEL
(C) Ceiling
CAL/OSHA PEL
8-hour TWA
(ST) STEL
(C) Ceiling
Peak
PEL-TWA

10 µg/m³ [5 µg/m³ Action Level]

REL-TWA TLV-TWA PEL-TWA

0.01 mg/m³ [0.005 mg/m³ Action Level]

PEL-STEL REL-STEL TLV-STEL PEL-STEL
PEL-C REL-C

0.002 mg/m³ [15 minutes]

TLV-C PEL-C
Skin notation

N

Skin notation

N

Skin notation

N

Skin notation

N

Notes:

See See 29 CFR 1910.1018, Arsenic.

Notes:

CARCINOGEN (Ca): REDUCE EXPOSURE TO LOWEST FEASIBLE CONCENTRATION. See Appendix A, NIOSH Potential Occupational Carcinogens.

Notes:

Visit the ACGIH TLV site for specific data
BEI®. TLV for lead arsenate (3687-31-8) was withdrawn for insufficient data in 2009.

Notes:
Health factors:  See NIH-NLM PubChem. IDLH

5 mg/m³

Carcinogenic classifications: EPA-A, IARC-1, NIOSH-Ca, NTP-K, OSHA-Ca, TLV-A1 Notes:

Ca

AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:

Additional Resources and Literature References

Last Updated Date : 04/03/2024