1,1,1,2-TETRACHLORO-2,2-DIFLUOROETHANE†
| CAS # | 76-11-9 |
|---|---|
| Formula |
CCl₃CClF₂ |
| Synonyms |
2,2-difluoro-1,1,1,2-tetrachloroethane; Freon(R) 112a; Halocarbon 112a; Refrigerant 112a |
| Physical description | Colorless solid with a slight, ether-like odor. | ||
|---|---|---|---|
| Boiling point | 197°F | Molecular weight | 203.8 |
| Freezing point/melting point | 105°F | Vapor pressure | 40 mmHg |
| Flash point | Vapor density | ||
| Specific gravity | 1.65 | Ionization potential | |
| Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
| NFPA health rating | NFPA fire rating | ||
| NFPA reactivity rating | NFPA special instruction | ||
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | 2337 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | CSC tube (100/50 mg) [SKC 226-01] |
| Sampling time* | |
| Sampling volume (TWA)* | 0.5-2 L |
| Sampling flow rate (TWA)* | 0.01-0.035 L/min |
| Sampling volume (STEL/Peak/C)* | |
| Sampling flow rate (STEL/Peak/C)* | |
| Analytical method instruments | GC-FID |
| Method reference | NIOSH 1016 (partially validated) |
| Notes | |
| Special requirements |
|
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media |
|
|---|---|
| Bulk Method |
|
| Device | |||||
|---|---|---|---|---|---|
| Model/Type | |||||
|
Sampling information (see manufacturer instructions) |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA |
500 ppm (4170 mg/m³) |
REL-TWA |
500 ppm (4170 mg/m³) |
TLV-TWA |
100 ppm [2007] |
PEL-TWA |
500 ppm (4170 mg/m³) |
| PEL-STEL |
|
REL-STEL |
|
TLV-STEL |
|
PEL-STEL |
|
| PEL-C |
|
REL-C |
|
TLV-C |
|
PEL-C |
|
| Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
| Notes: |
Notes:
|
Notes:
|
Notes:
|
||||
| Health factors: See NIH-NLM PubChem. | IDLH | ||||||
| Carcinogenic classifications: Not listed |
Notes:
|
||||||
|
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:
|
|||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - 1,1,1,2-tetrachloro-2,2-difluoroethane NIOSH: Pocket Guide to Chemical Hazards - 1,1,1,2-Tetrachloro-2,2-difluoroethane Literature References
|
Last Updated Date : 12/19/2018
CHLOROPICRIN (NITROTRICHLOROMETHANE)†
| CAS # | 76-06-2 |
|---|---|
| Formula |
CCl₃NO₂ |
| Synonyms |
nitrochloroform; nitrotrichloromethane; trichloronitromethane |
| Physical description | Colorless to faint-yellow, oily liquid with an intensely irritating odor. | ||
|---|---|---|---|
| Boiling point | 234°F | Molecular weight | 164.4 |
| Freezing point/melting point | -93°F | Vapor pressure | 18 mmHg |
| Flash point | Vapor density | 5.7 | |
| Specific gravity | 1.66 | Ionization potential | |
| Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
| NFPA health rating | 4 | NFPA fire rating | 0 |
| NFPA reactivity rating | 3 | NFPA special instruction | |
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | 0675 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | 2 XAD-4 tubes in series (80/40 mg) [SKC 226-93] |
| Sampling time* | 25 min |
| Sampling volume (TWA)* | 5 L |
| Sampling flow rate (TWA)* | 0.2 L/min |
| Sampling volume (STEL/Peak/C)* | |
| Sampling flow rate (STEL/Peak/C)* | |
| Analytical method instruments | GC-ECD |
| Method reference | OSHA PV2103 (partially validated) |
| Notes | Samples should be protected from light after sampling by covering them with the OSHA-21 form, or an opaque tape, such as masking tape. |
| Special requirements |
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media | |
|---|---|
| Bulk Method | Available |
| Device | Detector tube | Infrared spectrophotometer |
|---|---|---|
| Model/Type | Gastec 134 | Miran 1A & 1B |
|
Sampling information (see manufacturer instructions) |
1-60 ppm range | 0.1 ppm@11.5 µm |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA |
0.1 ppm (0.7 mg/m³) |
REL-TWA |
0.1 ppm (0.7 mg/m³) |
TLV-TWA | PEL-TWA |
0.1 ppm (0.7 mg/m³) |
|
| PEL-STEL | REL-STEL | TLV-STEL | PEL-STEL | ||||
| PEL-C | REL-C | TLV-C | PEL-C | ||||
| Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
| Notes: | Notes: |
Notes:
Visit the ACGIH TLV site for specific data |
Notes: | ||||
| Health factors: See NIH-NLM PubChem. | IDLH |
2 ppm |
|||||
| Carcinogenic classifications: TLV-A4 | Notes: | ||||||
|
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:
0.075 ppm/0.15 ppm/1.5 ppm |
|||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - Chloropicrin NIOSH: Pocket Guide to Chemical Hazards - Chloropicrin Literature References
|
Last Updated Date : 05/03/2024
TRICHLOROACETIC ACID
| CAS # | 76-03-9 |
|---|---|
| Formula |
C₂HCl₃O₂ |
| Synonyms |
TCA; trichloroethanoic acid |
| Physical description | Colorless to white, crystalline solid with a sharp, pungent odor. | ||
|---|---|---|---|
| Boiling point | 388°F | Molecular weight | 163.39 |
| Freezing point/melting point | 136°F | Vapor pressure | 1 mmHg at 124°F |
| Flash point | Vapor density | 5.6 | |
| Specific gravity | 1.62 | Ionization potential | |
| Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
| NFPA health rating | NFPA fire rating | ||
| NFPA reactivity rating | NFPA special instruction | ||
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | T337 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | Silica gel tube (100/50 mg) [SKC 226-47-01] |
| Sampling time* | |
| Sampling volume (TWA)* | 10 L |
| Sampling flow rate (TWA)* | 0.2 L/min |
| Sampling volume (STEL/Peak/C)* | |
| Sampling flow rate (STEL/Peak/C)* | |
| Analytical method instruments | HPLC-UV |
| Method reference | OSHA PV2017 (partially validated) |
| Notes | |
| Special requirements |
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media | |
|---|---|
| Bulk Method |
| Device | |||||
|---|---|---|---|---|---|
| Model/Type | |||||
|
Sampling information (see manufacturer instructions) |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA | REL-TWA |
1 ppm (7 mg/m³) |
TLV-TWA |
0.5 ppm [2013] |
PEL-TWA |
1 ppm (5 mg/m³) |
|
| PEL-STEL | REL-STEL | TLV-STEL | PEL-STEL | ||||
| PEL-C | REL-C | TLV-C | PEL-C | ||||
| Skin notation |
NA |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
|
Notes:
Not established |
Notes: | Notes: | Notes: | ||||
| Health factors: See NIH-NLM PubChem. | IDLH | ||||||
| Carcinogenic classifications: IARC-3, TLV-A3, EPA-C | Notes: | ||||||
| AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3: | |||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - Trichloroacetic acid NIOSH: Pocket Guide to Chemical Hazards - Trichloroacetic acid Literature References
|
Last Updated Date : 01/29/2021
2,2-DICHLOROPROPIONIC ACID
| CAS # | 75-99-0 |
|---|---|
| Formula |
C₃H₄Cl₂O₂ |
| Synonyms |
2-dichloropropionic acid; Basfapon; Basafapon B; Basfapon/N; BH dalapon; Basinex; Crisapon; Davpon; Gramevin; Kenapon; Uropon; Dalapon; Ded-weed; Dowpon Proprop; Radapon; Revenge; Unipon |
| Physical description | Colorless liquid with an acrid odor. | ||
|---|---|---|---|
| Boiling point | 374°F | Molecular weight | 143.0 |
| Freezing point/melting point | 46°F | Vapor pressure | 5.07 mmHg at 160°F |
| Flash point | Vapor density | 4.9 | |
| Specific gravity | 1.40 | Ionization potential | |
| Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
| NFPA health rating | NFPA fire rating | ||
| NFPA reactivity rating | NFPA special instruction | ||
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | D176 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | Silica gel tube (150/75 mg) [SKC 226-10] |
| Sampling time* | |
| Sampling volume (TWA)* | 10 L |
| Sampling flow rate (TWA)* | 0.2 L/min |
| Sampling volume (STEL/Peak/C)* | |
| Sampling flow rate (STEL/Peak/C)* | |
| Analytical method instruments | HPLC-UV |
| Method reference | OSHA PV2017 (partially validated) |
| Notes | |
| Special requirements |
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media |
|
|---|---|
| Bulk Method |
|
| Device | |||||
|---|---|---|---|---|---|
| Model/Type | |||||
|
Sampling information (see manufacturer instructions) |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA |
|
REL-TWA |
1 ppm (6 mg/m³) |
TLV-TWA |
5 mg/m³ (inhalable particulate matter) [1997] |
PEL-TWA |
1 ppm (6 mg/m³) |
| PEL-STEL |
|
REL-STEL |
|
TLV-STEL |
|
PEL-STEL |
|
| PEL-C |
|
REL-C |
|
TLV-C |
|
PEL-C |
|
| Skin notation |
NA |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
|
Notes:
Not established |
Notes:
|
Notes:
|
Notes:
|
||||
| Health factors: See NIH-NLM PubChem. | IDLH | ||||||
| Carcinogenic classifications: TLV-A4 |
Notes:
|
||||||
|
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:
|
|||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - 2,2-Dichloropropionic acid NIOSH: Pocket Guide to Chemical Hazards - 2,2-Dichloropropionic acid Literature References
|
Last Updated Date : 12/15/2020
2,2-DIMETHYLBUTANE
| CAS # | 75-83-2 |
|---|---|
| Formula |
C₆H₁₄ |
| Synonyms |
diethylmethylmethane; diisopropyl; 2,3-dimethylbutane; isohexane; neohexane |
| Physical description | Clear liquids with mild, gasoline-like odors. | ||
|---|---|---|---|
| Boiling point | 121.5°F | Molecular weight | 86.18 |
| Freezing point/melting point | -148°F | Vapor pressure | 274 mmHg |
| Flash point | -54°F | Vapor density | 3 |
| Specific gravity | 0.649 | Ionization potential | |
| Lower explosive limit (LEL) | 1.2% | Upper explosive limit (UEL) | 7% |
| NFPA health rating | 2 | NFPA fire rating | 3 |
| NFPA reactivity rating | 0 | NFPA special instruction | |
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | |
|---|---|
| Sampling group | |
| Sampler/Sampling media | |
| Sampling time* |
|
| Sampling volume (TWA)* |
|
| Sampling flow rate (TWA)* |
|
| Sampling volume (STEL/Peak/C)* |
|
| Sampling flow rate (STEL/Peak/C)* |
|
| Analytical method instruments | |
| Method reference | |
| Notes | |
| Special requirements |
|
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media |
|
|---|---|
| Bulk Method |
|
| Device | |||||
|---|---|---|---|---|---|
| Model/Type | |||||
|
Sampling information (see manufacturer instructions) |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA |
|
REL-TWA |
100 ppm (350 mg/m³) |
TLV-TWA |
500 ppm [1979] |
PEL-TWA |
500 ppm (1800 mg/m³) |
| PEL-STEL |
|
REL-STEL |
|
TLV-STEL |
1000 ppm [1979] |
PEL-STEL |
1000 ppm (3600 mg/m³) |
| PEL-C |
|
REL-C |
510 ppm (1800 mg/m³) [15 minutes] |
TLV-C |
|
PEL-C |
|
| Skin notation |
NA |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
|
Notes:
Not established |
Notes:
|
Notes:
|
Notes:
|
||||
| Health factors: See NIH-NLM PubChem. | IDLH | ||||||
| Carcinogenic classifications: Not listed |
Notes:
|
||||||
|
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:
|
|||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - Neohexane NIOSH: Pocket Guide to Chemical Hazards - Hexane isomers (excluding n-Hexane) Literature References
|
Last Updated Date : 12/15/2020
LITHIUM HYDRIDE†
| CAS # | 7580-67-8 |
|---|---|
| Formula |
HLi |
| Synonyms |
lithium monohydride |
| Physical description | Odorless, off-white to gray, translucent, crystalline mass or white powder. | ||
|---|---|---|---|
| Boiling point | decomposes | Molecular weight | 7.95 |
| Freezing point/melting point | 1256°F | Vapor pressure | 0 mmHg (approx) |
| Flash point | Vapor density | ||
| Specific gravity | 0.78 | Ionization potential | |
| Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
| NFPA health rating | 3 | NFPA fire rating | 2 |
| NFPA reactivity rating | 2 | NFPA special instruction | W: Reacts violently or explosively with water. |
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | 1503 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | Pre-assembled cassette with mixed cellulose ester filter (MCEF) 0.8 micron (25 or 37 mm) [MAWP025A0 or MAWP037A0] |
| Sampling time* | 240-480 min |
| Sampling volume (TWA)* | 480-960 L |
| Sampling flow rate (TWA)* | 2 L/min |
| Sampling volume (STEL/Peak/C)* | |
| Sampling flow rate (STEL/Peak/C)* | |
| Analytical method instruments | AAS/AES |
| Method reference | OSHA ID-121 (fully validated) |
| Notes | Results will be reported from the elemental analysis for the element only; the stated identity of the actual sample contents is based on the assumption that the material sampled is as identified by the compliance officer using available documentation of materials and processes. An elemental result provided may be converted to the desired compound by multiplying the result by the appropriate stoichiometric factor. A 91B report specific to the compound (including the stoichiometric conversion) may by be provided upon request by contacting the laboratory. The stoichiometric factor for lithium hydride from lithium is 1.145. Analysis for this analyte is based on water solubility. |
| Special requirements |
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media | |
|---|---|
| Bulk Method |
| Device | |||||
|---|---|---|---|---|---|
| Model/Type | |||||
|
Sampling information (see manufacturer instructions) |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA |
0.025 mg/m³ |
REL-TWA |
0.025 mg/m³ |
TLV-TWA | PEL-TWA |
0.025 mg/m³ |
|
| PEL-STEL | REL-STEL | TLV-STEL | PEL-STEL | ||||
| PEL-C | REL-C | TLV-C |
0.05 mg/m³ (inhalable particulate matter) [2014] |
PEL-C | |||
| Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
| Notes: | Notes: | Notes: | Notes: | ||||
| Health factors: See NIH-NLM PubChem. | IDLH |
0.5 mg/m³ |
|||||
| Carcinogenic classifications: Not listed | Notes: | ||||||
|
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:
0.025 mg/m³/0.1 mg/m³/3 mg/m³ |
|||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - Lithium hydride NIOSH: Pocket Guide to Chemical Hazards - Lithium hydride Literature References
|
Last Updated Date : 01/04/2021
TETRAMETHYL LEAD (as Pb)†
| CAS # | 75-74-1 |
|---|---|
| Formula |
C₄H₁₂Pb |
| Synonyms |
lead tetramethyl; tetramethylplumbane; TML |
| Physical description | Colorless liquid (unless dyed red, orange, or blue) with a fruity odor. | ||
|---|---|---|---|
| Boiling point | 230°F at 10 mmHg (decomposes above 212°F) | Molecular weight | 267.33 |
| Freezing point/melting point | -17.5°F | Vapor pressure | 23 mmHg |
| Flash point | 100°F | Vapor density | 6.5 |
| Specific gravity | 1.995 | Ionization potential | 8.50 eV |
| Lower explosive limit (LEL) | 1.8% | Upper explosive limit (UEL) | |
| NFPA health rating | 2 | NFPA fire rating | 3 |
| NFPA reactivity rating | 3 | NFPA special instruction | W: Reacts violently or explosively with water. |
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | 2370 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | XAD-2 tube (400/200 mg) [SKC 226-30-06] |
| Sampling time* | |
| Sampling volume (TWA)* | 15-100 L |
| Sampling flow rate (TWA)* | 0.01 - 0.2 L/min |
| Sampling volume (STEL/Peak/C)* | |
| Sampling flow rate (STEL/Peak/C)* | |
| Analytical method instruments | GC-PID |
| Method reference | NIOSH 2534 (fully validated) |
| Notes | |
| Special requirements |
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media | |
|---|---|
| Bulk Method |
| Device | |||||
|---|---|---|---|---|---|
| Model/Type | |||||
|
Sampling information (see manufacturer instructions) |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA |
0.075 mg/m³ |
REL-TWA |
0.075 mg/m³ |
TLV-TWA |
0.15 mg/m³ [1992] |
PEL-TWA | |
| PEL-STEL | REL-STEL | TLV-STEL | PEL-STEL | ||||
| PEL-C | REL-C | TLV-C |
0.075 mg/m³ [1992] |
PEL-C | |||
| Skin notation |
Y |
Skin notation |
Y |
Skin notation |
Y |
Skin notation |
Y |
|
Notes:
See 29 CFR 1910.1000 Table Z-1. OSHA Construction and Maritime Industry PELs are 0.15 mg/m³. See 29 CFR 1926.55 Table 1 and 29 CFR 1915.1000 Table Z-Shipyards. |
Notes: | Notes: | Notes: | ||||
| Health factors: See NIH-NLM PubChem. | IDLH |
40 mg/m³ |
|||||
| Carcinogenic classifications: IARC-3 | Notes: | ||||||
| AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3: | |||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - Tetramethyllead NIOSH: Pocket Guide to Chemical Hazards - Tetramethyl lead (as Pb) Literature References
|
Last Updated Date : 06/03/2022
DICHLOROACETYLENE†
| CAS # | 7572-29-4 |
|---|---|
| Formula |
C₂Cl₂ |
| Synonyms |
DCA; dichloroethyne |
| Physical description | Volatile oil with a disagreeable, sweetish odor. | ||
|---|---|---|---|
| Boiling point | 90°F (explodes) | Molecular weight | 94.9 |
| Freezing point/melting point | -58 to -87°F | Vapor pressure | |
| Flash point | Vapor density | ||
| Specific gravity | 1.26 | Ionization potential | |
| Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
| NFPA health rating | NFPA fire rating | ||
| NFPA reactivity rating | NFPA special instruction | ||
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | 0865 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | |
| Sampling time* | |
| Sampling volume (TWA)* | |
| Sampling flow rate (TWA)* | |
| Sampling volume (STEL/Peak/C)* | |
| Sampling flow rate (STEL/Peak/C)* | |
| Analytical method instruments | |
| Method reference | |
| Notes | |
| Special requirements |
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media | |
|---|---|
| Bulk Method |
| Device | |||||
|---|---|---|---|---|---|
| Model/Type | |||||
|
Sampling information (see manufacturer instructions) |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA | REL-TWA | TLV-TWA | PEL-TWA | ||||
| PEL-STEL | REL-STEL | TLV-STEL | PEL-STEL | ||||
| PEL-C |
0.1 ppm (0.4 mg/m³) OSHA Construction and Maritime industries only. |
REL-C |
0.1 ppm (0.4 mg/m³) |
TLV-C |
0.1 ppm [1992] |
PEL-C |
0.1 ppm (0.4 mg/m³) |
| Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
|
Notes:
The OSHA PEL applies to Construction and Maritime Industries only. See 29 CFR 1926.55 Table 1 and 29 CFR 1915.1000 Table Z-Shipyards. |
Notes:
CARCINOGEN (Ca): REDUCE EXPOSURE TO LOWEST FEASIBLE CONCENTRATION. See Appendix A. |
Notes: | Notes: | ||||
| Health factors: See NIH-NLM PubChem. | IDLH | ||||||
| Carcinogenic classifications: IARC-3, NIOSH-Ca, TLV-A3 |
Notes:
Ca |
||||||
| AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3: | |||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - Dichloroacetylene NIOSH: Pocket Guide to Chemical Hazards - Dichloroacetylene Literature References
|
Last Updated Date : 06/02/2022
DICHLORODIFLUOROMETHANE†
| CAS # | 75-71-8 |
|---|---|
| Formula |
CCl₂F₂ |
| Synonyms |
difluorodichloromethane; Fluorocarbon 12; Freon12; Genetron12; Halon122; Propellant 12; Refrigerant 12 |
| Physical description | Colorless gas with an ether-like odor at extremely high concentrations. | ||
|---|---|---|---|
| Boiling point | -22°F | Molecular weight | 120.9 |
| Freezing point/melting point | -252°F | Vapor pressure | 5.7 atm |
| Flash point | Vapor density | 4.2 | |
| Specific gravity | 1.35 at 59°F | Ionization potential | 11.75 eV |
| Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
| NFPA health rating | NFPA fire rating | ||
| NFPA reactivity rating | NFPA special instruction | ||
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | 0871 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | |
| Sampling time* | |
| Sampling volume (TWA)* | |
| Sampling flow rate (TWA)* | |
| Sampling volume (STEL/Peak/C)* | |
| Sampling flow rate (STEL/Peak/C)* | |
| Analytical method instruments | |
| Method reference | |
| Notes | OSHA staff, please contact the SLTC before sampling (801) 233-5100. |
| Special requirements |
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media | |
|---|---|
| Bulk Method |
| Device | |||||
|---|---|---|---|---|---|
| Model/Type | |||||
|
Sampling information (see manufacturer instructions) |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA |
1000 ppm (4950 mg/m³) |
REL-TWA |
1000 ppm (4950 mg/m³) |
TLV-TWA |
1000 ppm [1979] |
PEL-TWA |
1000 ppm (4950 mg/m³) |
| PEL-STEL | REL-STEL | TLV-STEL | PEL-STEL | ||||
| PEL-C | REL-C | TLV-C | PEL-C |
6200 ppm |
|||
| Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
| Notes: | Notes: | Notes: | Notes: | ||||
| Health factors: See NIH-NLM PubChem. | IDLH |
15000 ppm |
|||||
| Carcinogenic classifications: TLV-A4 | Notes: | ||||||
| AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3: | |||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - Dichlorodifluoromethane NIOSH: Pocket Guide to Chemical Hazards - Dichlorodifluoromethane Literature References
|
Last Updated Date : 01/22/2024
FLUOROTRICHLOROMETHANE (TRICHLOROFLUOROMETHANE)†
| CAS # | 75-69-4 |
|---|---|
| Formula |
CCl₃F |
| Synonyms |
trichlorofluoromethane; Freon 11; monofluorotrichloromethane; Refrigerant 11; trichloromonofluoromethane |
| Physical description | Colorless to water-white, nearly odorless liquid or gas (above 75°F). | ||
|---|---|---|---|
| Boiling point | 75°F | Molecular weight | 137.4 |
| Freezing point/melting point | -168°F | Vapor pressure | 690 mmHg |
| Flash point | Vapor density | 4.74 | |
| Specific gravity | 1.47 | Ionization potential | 11.77 eV |
| Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
| NFPA health rating | NFPA fire rating | ||
| NFPA reactivity rating | NFPA special instruction | ||
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | 1285 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | CSC tube (400/200 mg) [SKC 226-09] |
| Sampling time* | |
| Sampling volume (TWA)* | 0.3-7 L |
| Sampling flow rate (TWA)* | 0.05 L/min |
| Sampling volume (STEL/Peak/C)* |
|
| Sampling flow rate (STEL/Peak/C)* |
|
| Analytical method instruments | GC-FID |
| Method reference | NIOSH 1006 (fully validated) |
| Notes |
|
| Special requirements |
|
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media |
|
|---|---|
| Bulk Method |
|
| Device | Infrared spectrophotometer | Infrared spectrophotometer | Organic vapor analyzer |
|---|---|---|---|
| Model/Type | Miran 1A & 1B | Miran 103 | |
|
Sampling information (see manufacturer instructions) |
1.4 ppm@11 µm | 0-100 ppm@10.8 µm |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA |
1000 ppm (5600 mg/m³) |
REL-TWA |
|
TLV-TWA |
|
PEL-TWA |
|
| PEL-STEL |
|
REL-STEL |
|
TLV-STEL |
|
PEL-STEL |
|
| PEL-C |
|
REL-C |
1000 ppm (5600 mg/m³) |
TLV-C |
1000 ppm [1992] |
PEL-C |
1000 ppm (5600 mg/m³) |
| Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
| Notes: |
Notes:
|
Notes:
|
Notes:
|
||||
| Health factors: See NIH-NLM PubChem. | IDLH |
2000 ppm |
|||||
| Carcinogenic classifications: TLV-A4 |
Notes:
|
||||||
|
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:
|
|||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - Trichlorofluoromethane NIOSH: Pocket Guide to Chemical Hazards - Fluorotrichloromethane Literature References
|
Last Updated Date : 01/12/2023