Inspection Detail
Inspection: 936804.015 - Centennial Moisture Control, Inc.
Inspection Information - Office: Dallas Area Office
Site Address:
Centennial Moisture Control, Inc.
3032 Brinkley Avenue
Dallas, TX 75205
Mailing Address:
1780 Hurd Drive, Irving, TX 75038
Union Status: NonUnion
SIC:
NAICS: 238990/All Other Specialty Trade Contractors
Inspection Type: Fat/Cat
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 08/31/2013
Emphasis: N:Silica, L:Constr6
Case Closed: 03/18/2016
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 848907 | ||
| Inspection | 941680 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $26,390 | $0 | $0 | $0 | $0 | $26,390 |
| Current Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100134 C01 | 02/21/2014 | 03/05/2014 | $7,000 | $5,390 | $0 | 03/04/2014 | F - Formal Settlement | |
| 2. | 01001B | Serious | 19100134 C03 | 02/21/2014 | 03/05/2014 | $0 | $0 | $0 | 03/04/2014 | F - Formal Settlement | |
| 3. | 01001C | Serious | 19100134 I01 II | 02/21/2014 | 03/05/2014 | $0 | $7,000 | $0 | 03/04/2014 | F - Formal Settlement | |
| 4. | 01001D | Serious | 19100134 I07 | 02/21/2014 | 03/05/2014 | $0 | $7,000 | $0 | 03/04/2014 | F - Formal Settlement | |
| 5. | 01003 | Serious | 19100134 I05 I | 02/21/2014 | 03/05/2014 | $0 | $7,000 | $0 | 03/04/2014 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
At 9:18 a.m. on August 31, 2013, Employee #1 was wearing a supplied-air respirator to sandblast the seating bowl area of an indoor arena. The breathing hose to the airline respirator was connected to an airline filter. The inlet side of the airline filter was connected to a pneumatic hose that was connected to other pneumatic hoses in a series. The inlet side of the upstream pneumatic hose was connected to the discharge side of a diesel-driven Ingersoll rand air compressor which was stationed underneath the arena crash wall. The air compressor malfunctioned and began to smoke, causing the employee to breathe the contaminated air. The air compressor was not situated to prevent entry of the contaminated air into the air-supply system; and the airline filter was not capable of removing carbon monoxide and other toxic gases from the air stream. Employee #1 collapsed to the ground floor and was found unresponsive by coworkers. The employee was pronounced dead at the site.
Keywords: Air Line, Air Line Respirator, Asphyxiated, Chemical Vapor, Collapse, Compressor, Hose, Sandblasting, Unconsciousness
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 936804.015 | 52 | M | Fatality | Occupation not reported |
Translate