Inspection Detail
Inspection: 313775454 - Lao K Llc
Inspection Information - Office: Eugene
Site Address:
Lao K Llc
610 Sw Queen Ave
Albany, OR 97322
Mailing Address:
3637 Nw Goldfinch Dr, Corvallis, OR 97330
Union Status: NonUnion
SIC:8734
NAICS: 541380/Testing Laboratories
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 06/15/2010
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 12/09/2010
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 5 | 5 | ||||
| Current Violations | 5 | 5 | ||||
| Initial Penalty | $4,800 | $0 | $0 | $0 | $0 | $4,800 |
| Current Penalty | $3,300 | $0 | $0 | $0 | $0 | $3,300 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 701076001 C | 08/09/2010 | 02/26/2010 | $1,250 | $1,250 | $0 | 08/25/2010 | L - State Settlement | |
| 2. | 01002 | Serious | 19100307 C02 I | 08/09/2010 | 06/15/2010 | $375 | $1,500 | $0 | 08/25/2010 | L - State Settlement | |
| 3. | 01003A | Serious | 19100134 C01 | 08/09/2010 | 06/15/2010 | $125 | $500 | $0 | 08/25/2010 | L - State Settlement | |
| 4. | 01003B | Serious | 19100134 C01 VIII | 08/09/2010 | 06/15/2010 | $0 | $0 | $0 | 08/25/2010 | L - State Settlement | |
| 5. | 01003C | Serious | 19100134 E01 | 08/09/2010 | 06/15/2010 | $0 | $0 | $0 | 08/25/2010 | L - State Settlement | |
| 6. | 01004A | Serious | 19100132 D02 | 08/09/2010 | 02/26/2010 | $1,250 | $1,250 | $0 | 08/25/2010 | L - State Settlement | |
| 7. | 01004B | Serious | 19100132 A | 08/09/2010 | 06/15/2010 | $0 | $0 | $0 | 08/25/2010 | L - State Settlement | |
| 8. | 01005 | Serious | 701076501 | 08/09/2010 | 06/15/2010 | $300 | $300 | $0 | 08/25/2010 | L - State Settlement |
Investigation Summary
Employees #1 and #2 were working near a reaction vessel. The rapidly rising temperature in the vessel caused liquid and steam to erupt out of the vessel and onto both employees. They suffered serious burns to their face, arms, and back and were hospitalized. Further investigation revealed that the temperature of exothermic reaction was not controlled adequately.
Keywords: STEAM, BURN, CHEMICAL VESSEL, BACK, CHEMICAL REACTION, ARM, FACE, PRESSURE RELEASE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 313775454 | Hospitalized injury | Burn/Scald(Heat) | Chemists, except biochemists |
Translate