Inspection: 313733610 - Randy Wagers Dba R & B Roofing
Inspection Information - Office: Ky Labor Cabinet Division Of Osh Compliance
Site Address:
Randy Wagers Dba R & B Roofing
13391 Hwy 421
Hyden, KY 41762
Mailing Address:
971 Curry Branch Rd, Manchester, KY 40962
Union Status: NonUnion
SIC:1761
NAICS: 238160/Roofing Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/09/2009
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 04/10/2015
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102499076 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 6 | 1 | 7 | |||
| Current Violations | 6 | 1 | 7 | |||
| Initial Penalty | $7,875 | $0 | $0 | $750 | $0 | $8,625 |
| Current Penalty | $6,375 | $0 | $0 | $500 | $0 | $6,875 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260451 F06 | 02/16/2010 | 02/22/2010 | $1,500 | $1,500 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19260451 G01 | 02/16/2010 | 02/22/2010 | $1,500 | $1,500 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19260454 A | 02/16/2010 | 02/22/2010 | $750 | $1,500 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19260501 B11 | 02/16/2010 | 02/22/2010 | $1,500 | $1,500 | $0 | I - Informal Settlement | ||
| 5. | 01005 | Serious | 19260503 A01 | 02/16/2010 | 02/22/2010 | $750 | $1,500 | $0 | I - Informal Settlement | ||
| 6. | 01006 | Serious | 19261053 B01 | 02/16/2010 | 02/22/2010 | $375 | $375 | $0 | I - Informal Settlement | ||
| 7. | 02001 | Other | 201800302 | 02/16/2010 | 11/03/2009 | $500 | $750 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 11:00 a.m. on November 2, 2009, Employee #1 was working from a ladder jack scaffold. He was installing drip edge on a house. When he raised a 10 ft piece of aluminum drip edge to install it, it contacted a 19,900 volt overhead power line located approximately 4 ft above the roof peak. Employee #1 was shocked. He fell from the scaffold to the ground 20 ft below. Employee #1 suffered lacerations, electrical burns and internal injuries. He died at the hospital while being treated.
Keywords: RAIN SPOUT, SHOCK, ELECTROCUTED, ELECTRIC SHOCK, FALL, FALL PROTECTION, SCAFFOLD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 313733610 | Fatality | Electric Shock | Roofers |