Inspection Detail
Inspection: 313693509 - Jencast Products, Inc.
Inspection Information - Office: Oklahoma City Area Office
Site Address:
Jencast Products, Inc.
500 W. 4th Street
South Coffeyville, OK 74072
Mailing Address:
500 W. 4th Street, South Coffeyville, OK 74072
Union Status: NonUnion
SIC:3321
NAICS: 331511/Iron Foundries
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/16/2010
Emphasis:
Case Closed: 11/01/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100647171 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $16,000 | $0 | $0 | $0 | $0 | $16,000 |
| Current Penalty | $8,000 | $0 | $0 | $0 | $0 | $8,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100254 D06 | 01/03/2011 | 01/07/2011 | $4,000 | $4,000 | $0 | 01/20/2011 | F - Formal Settlement | Citation has been deleted. |
| 2. | 01002 | Serious | 19100254 D09 III | 01/03/2011 | 01/11/2011 | $4,000 | $4,000 | $0 | 01/20/2011 | - | |
| 3. | 01003A | Serious | 19100303 B01 | 01/03/2011 | 01/11/2011 | $0 | $4,000 | $0 | 01/20/2011 | F - Formal Settlement | |
| 4. | 01003B | Serious | 19100303 B02 | 01/03/2011 | 01/11/2011 | $0 | $0 | $0 | 01/20/2011 | - | |
| 5. | 01003C | Serious | 19100305 G02 III | 01/03/2011 | 01/11/2011 | $0 | $0 | $0 | 01/20/2011 | - | |
| 6. | 01004 | Serious | 19100334 B02 I | 01/03/2011 | 01/07/2011 | $4,000 | $4,000 | $0 | 01/20/2011 | - |
Investigation Summary
A supervisor had just finished welding a part for a Wheelabrator blaster and had placed the electrode end of the welding lead on the floor in contact with the machine's base structure. An employee was assisting the supervisor. The employee was on the table of the blaster, starting to pick up tools. When the employee removed the ground lead, he received an electric shock. He fell from the table and struck his head on the floor. He was transported to a medical center, where he was pronounced dead.
Keywords: HEAD, E GI III, ELECTRICAL, WELDING, GROUND FAULT, WELDING CABLE, ELECTRIC SHOCK, FALL, WELDING ELECTRODE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 313693509 | Fatality | Electric Shock | Occupation not reported |
Translate