Inspection Detail
Inspection: 313511685 - Ameron International Water Transmission Group
Inspection Information - Office: San Bernardino District Office
Site Address:
Ameron International Water Transmission Group
12455 Arrow Route
Rancho Cucamonga, CA 91739
Mailing Address:
12455 Arrow Route, Rancho Cucamonga, CA 91739
Union Status: Union
SIC:3272
NAICS: 327332/Concrete Pipe Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/05/2011
Emphasis:
Case Closed: 10/06/2022
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102616448 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $24,750 | $0 | $0 | $375 | $0 | $25,125 |
| Current Penalty | $14,000 | $0 | $0 | $1,125 | $0 | $15,125 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 5021 A | 08/05/2011 | 08/10/2011 | $375 | $375 | $0 | 09/02/2011 | F - Formal Settlement | |
| 2. | 02001 | Other | 3203 A | 08/05/2011 | 08/23/2011 | $750 | $6,750 | $0 | 09/02/2011 | F - Formal Settlement | |
| 3. | 03001 | Serious | 4999 C01 | 08/05/2011 | 08/23/2011 | $14,000 | $18,000 | $0 | 09/02/2011 | F - Formal Settlement |
Investigation Summary
At approximately 12:53 p.m. on February 11, 2012, an employee had used the sledge hammer to break the concrete lining from the inside of the pipe, approximately 10-feet 5 inches long, total length at that time, since he encountered difficulty in separating the pipe. The pipe had been torch-cut earlier using oxy-acetylene torch. Then, the employee applied tension to one side of the cut pipe using two sling hooks supported by the 30-ton Gantry crane. When the two pieces inadvertently got separated, one piece, 97.125-in. OD by 64-in. long, beveled, approximately 4,600 lbs, fell off the trunnion rollers, skipped a few times away from the side of the trunnion roller's frame and struck the employee in the back as the pipe landed on the ground cutting him in half towards his upper torso. The other section of the separated pipe (approximately 61.375-in. long), beveled, fell and rested onto another trunnion rollers at a lower level. The fatality was reported by the employer to DOSH San Bernardino District Office on February 11, 2011 at or about 1:40 pm. The employer was primarily engaged in the manufacture of concrete-steel pipe for water transmission purposes.
Keywords: ACETYLENE TORCH, LINE CONNECTOR, PLUMBING, STRUCK BY, FALLING OBJECT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 313511685 | Fatality | Other | Plumber, pipefitter and steamfiter apprentices |
Translate