Inspection Detail
Inspection: 1692860.015 - Inframark, Llc.
Inspection Information - Office: Atlanta East Area Office
Site Address:
Inframark, Llc.
250 Industrial Park Boulevard
Warner Robins, GA 31088
Mailing Address:
250 Industrial Park Boulevard, Warner Robins, GA 31088
Union Status: NonUnion
SIC:
NAICS: 221320/Sewage Treatment Facilities
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 08/22/2023
Emphasis:
Case Closed: 11/15/2023
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 2103591 | Yes |
Investigation Summary
At 10:00 a.m. on August 18, 2023, an employee was replacing the stand and bearing of the rotary drum thicker machine outside of the waste treatment area. The employee became sick and went to sit down. He was taken to the hospital and later died. The coroner's report listed coronary heart disease with tobacco use as contributing factors.
Keywords: Coronary artery disease, Natural Causes, Preexisting Condition
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1692860.015 | 57 | M | Fatality | Machinery maintenance occupations |