Inspection Detail
Inspection: 1605332.015 - 152205 - All Cleaning Carolina, Llc
Inspection Information - Office: Nc Department Of Labor - Charlotte
Site Address:
152205 - All Cleaning Carolina, Llc
149 Homanit Usa Road
Mount Gilead, NC 27306
Mailing Address:
322 Keener Drive, Dallas, NC 28034
Union Status: NonUnion
SIC:7363
NAICS: 561320/Temporary Help Services
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/25/2022
Emphasis:
Case Closed: 02/17/2023
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1898825 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 12 | 12 | ||||
| Current Violations | 8 | 8 | ||||
| Initial Penalty | $31,000 | $0 | $0 | $0 | $0 | $31,000 |
| Current Penalty | $16,000 | $0 | $0 | $0 | $0 | $16,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100030 A03 III | 11/21/2022 | 02/16/2023 | $3,000 | $3,000 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100030 A03 IV | 11/21/2022 | 02/16/2023 | $0 | $3,000 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19100140 C10 I | 11/21/2022 | 02/16/2023 | $2,000 | $2,000 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19100140 C10 II | 11/21/2022 | 02/16/2023 | $0 | $2,000 | $0 | I - Informal Settlement | ||
| 5. | 01005 | Serious | 19100140 C18 | 11/21/2022 | 12/01/2022 | $0 | $3,000 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 6. | 01006 | Serious | 19100140 D01 II | 11/21/2022 | 02/16/2023 | $3,000 | $3,000 | $0 | I - Informal Settlement | ||
| 7. | 01007 | Serious | 19100146 D04 IV | 11/21/2022 | 12/01/2022 | $0 | $3,000 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 8. | 01008 | Serious | 19100146 D04 V | 11/21/2022 | 02/16/2023 | $3,000 | $3,000 | $0 | I - Informal Settlement | ||
| 9. | 01009A | Serious | 19100146 G01 | 11/21/2022 | 02/16/2023 | $3,000 | $3,000 | $0 | I - Informal Settlement | ||
| 10. | 01009B | Other | 19100146 G04 | 11/21/2022 | 02/16/2023 | $0 | $0 | $0 | I - Informal Settlement | ||
| 11. | 01010 | Serious | 19100146 G03 | 11/21/2022 | 01/13/2023 | $0 | $2,000 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 12. | 01011 | Serious | 19100146 I09 | 11/21/2022 | 12/01/2022 | $0 | $2,000 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 13. | 01012 | Serious | 19100146 K03 II | 11/21/2022 | 02/16/2023 | $2,000 | $2,000 | $0 | I - Informal Settlement |
Investigation Summary
On May 24, 2022, an employee was pressure washing the interior of a large horizontal duct. The employee was wearing a harness and was attached to a self-retracting lifeline (SRL). When the employee reached a section of the duct that dumped into a large vertical air-material separator (cyclone), the cable on his SRL failed and he fell into the cyclone. The employee fell approximately 84 feet to the bottom on the cyclone and was killed.
Keywords: Air Duct, Duct, Fall, Fall From Elevation, Lifeline, Pressure Wash
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1605332.015 | 48 | M | Fatality | Occupation not reported |