Inspection Detail
Inspection: 1579486.015 - Premier Casting Services, Inc.
Inspection Information - Office: Iowa 0751910
Site Address:
Premier Casting Services, Inc.
1750 Broadway
Waterloo, IA 50704
Mailing Address:
1750 Broadway P.O. Box 2702, Waterloo, IA 50704
Union Status: NonUnion
SIC:
NAICS: 331511/Iron Foundries
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/28/2022
Emphasis: N:Amputate, S:Amputate
Case Closed: 04/25/2022
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1868192 | Yes | Yes |
| Inspection | 1582311 | Yes | |
| Inspection | 1582297 | Yes |
Investigation Summary
At 5:15 a.m. on February 21, 2022, an employee was using a Harrington (Model Number NER010L, Serial Number 00040427) 1-ton hoist to lift an iron casting from a tote to the Line-D conveyor table. The part started to slip from the hook. The employee attempted to push the part back to the tote when it fell. This condition led to the amputation of the distal tips of the 4th and 5th digits of the left hand. The employee was hospitalized. The part was identified by the employer as #TR105017. The weight of the part was approximately 281.5 pounds.
Keywords: Amputated, Amputation, Casting, Conveyor, Finger, Hoist
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1579486.015 | 35 | M | Hospitalized injury | Hand grinding and polishing occupations |