Inspection Detail
Inspection: 1571003.015 - Beyel Brothers, Inc.
Inspection Information - Office: Orlando Area Office
Site Address:
Beyel Brothers, Inc.
99 Dover Ave.
Merritt Island, FL 32952
Mailing Address:
550 Cidco Rd., Cocoa, FL 32926
Union Status: NonUnion
SIC:
NAICS: 336611/Ship Building and Repairing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/05/2022
Emphasis: L:Maritime
Case Closed: 07/25/2022
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1849275 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19100134 C01 | 06/30/2022 | 08/17/2022 | $0 | $0 | $0 | Z - Issued | ||
| 2. | 01002 | Other | 19100157 E03 | 06/30/2022 | 08/17/2022 | $0 | $0 | $0 | Z - Issued | ||
| 3. | 01003 | Other | 19100305 G02 III | 06/30/2022 | 07/27/2022 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At 10:00 a.m. on December 22, 2021, an employee was installing a portable pump to drain water from a compartment when he grabbed an extension cord that had exposed wires. The employee suffered an electric shock and was treated without hospitalization.
Keywords: Compartment, Electric Cord, Electric Pump, Electric Shock, Electrical Wire, Pump, Water
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1571003.015 | 45 | M | Non Hospitalized injury | Sailors and deckhands |