Inspection Detail
Inspection: 1550616.015 - Arcosa Wind Towers Inc.
Inspection Information - Office: Oklahoma City Area Office
Site Address:
Arcosa Wind Towers Inc.
15300 Tiger Switch Rd
Tulsa, OK 74116
Mailing Address:
15300 Tiger Switch Rd, Tulsa, OK 74116
Union Status: NonUnion
SIC:
NAICS: 332312/Fabricated Structural Metal Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/31/2021
Emphasis: L:Hotdays
Case Closed: 02/15/2022
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1805583 | Yes | |
| Inspection | 1550725 | Yes |
Investigation Summary
At 8:20 p.m. on August 23, 2021, an employee working for a structural metal manufacturer was aligning edges of a metal ring that had just been rolled and were not lined up. The employee walked along the inside of the ring with one foot on each side of the seam hitting the back corner with a mallet to align the ring before tack welding was to be performed. When the employee hit the corner of the ring with the mallet, the metal came free and caught his leg between the sides. The employee was hospitalized to treat a broken right leg and a laceration to his ankle.
Keywords: Align, Aligning, Ankle, Broken, Broken Bone, Catch Point, Caught Between, Engineering Controls, Fracture, Hammer , Hand Tool, Inexperience, Insufficient Supervision, Laceration, Lack of Engineering Controls, Leg, Manufacturing, Metal, Misjudgment, Misjudgment of Hazardous Situation, Pinch Point, Pinched, Rolled, Unsafe Position, Walking Surface
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1550616.015 | 23 | M | Hospitalized injury |