Inspection Detail
Inspection: 1545860.015 - Airway Services Inc.
Inspection Information - Office: Iowa 0751910
Site Address:
Airway Services Inc.
2415 Adair Union Street Site #80
Creston, IA 50801
Mailing Address:
5001 Christoval Road, San Angelo, TX 76904
Union Status: NonUnion
SIC:
NAICS: 221115
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/03/2021
Emphasis:
Case Closed: 12/08/2021
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1792719 | Yes | |
| Inspection | 1545895 | Yes | |
| Inspection | 1545982 | Yes |
Investigation Summary
At 6:00 p.m. on July 28, 2021, Employee #1 was installing the last actuator to open the clamshell roof of the Nacelle. While stepping across the gear box and turning his body 180 degrees, the employee's left hand contacted the exterior of a LED light fixture. Employee #1 received a 230-volt electrical shock, resulting in a dislocated and fractured left shoulder. Emergency services transported the employee for treatment. Employee #1 was hospitalized.
Keywords: Dislocated, Electric Shock, Fracture, Installing, Lighting, Lightning, Roof, Shock, Shoulder
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1545860.015 | 36 | M | Hospitalized injury |
Translate