Investigation Summary
At 6:45 p.m. on June 24, 2021, an employee and a coworker were repairing an APV Heat Exchanger (Model R5 QUAD-DRIVE 2005, Serial 20043003001040) after being called from the pump shop. The employee observed that ketchup had stopped draining and no water was flowing. While loosening the clamps on a pipe connected to the heat exchanger, hot water unexpectedly discharged from the pipe and struck the employee. The employee sustained third-degree burns on the left hip, second-degree burns on the chest and stomach, and first- to second-degree burns on the right arm and left shoulder. The employee was hospitalized for treatment.
Keywords: Arm, Burn, Heat Exchanger, Hot Water, Pipe, Shoulder, Struck Against, Struck By
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1540220.015 | 30 | M | Hospitalized injury | Machinery maintenance occupations |