Investigation Summary
At 1:53 p.m. on October 7, 2020, an employee was servicing a fire extinguisher. The fire extinguisher exploded because of overpressure. The employee suffered a finger amputation, broken bones in the right arm, and bruises and cuts to the forehead. The employee was hospitalized.
Keywords: Amputated, Amputation, Arm, Broken Bone, Exploded, Explosion, Finger, Fire Extinguisher, Forehead, Laceration, Overpressure, Servicing
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1497200.015 | 52 | M | Hospitalized injury | Fire inspection and fire prevention occupations |