Inspection Detail
Inspection: 1483739.015 - Dsm Biomedical
Inspection Information - Office: Osha Philadelphia Area Office
Site Address:
Dsm Biomedical
735 Pennsylvania Drive
Exton, PA 19341
Mailing Address:
735 Pennsylvania Drive, Exton, PA 19341
Union Status: NonUnion
SIC:
NAICS: 339112/Surgical and Medical Instrument Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/08/2021
Emphasis: N:Amputate
Case Closed: 09/29/2023
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1621777 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $13,494 | $0 | $0 | $0 | $0 | $13,494 |
| Current Penalty | $0 | $0 | $0 | $13,494 | $0 | $13,494 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19100147 C04 I | 01/08/2021 | 01/14/2021 | $13,494 | $13,494 | $0 | I - Informal Settlement |
Investigation Summary
At 7:30 a.m. on July 11, 2020, an employee was servicing an exhaust fan when the deenergized fan began to move due to wind as there was no mechanical energy isolation device installed to prevent the fan from freely moving. The employee tried to stop the fan by grabbing the fan belt but his hand got pulled in and caught between the belt and the pully. The employee was hospitalized to treat an amputation of his thumb.
Keywords: Amputation, Caught Between, Caught In, Exhaust System, Fan, Fan Belt, Lockout/Tagout, Pulley, Thumb
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1483739.015 | 58 | M | Hospitalized injury | Technicians, n.e.c. |
Translate