Inspection Detail
Inspection: 1464032.015 - Di Industrial Coatings, Inc.
Inspection Information - Office: Sacramento District Office
Site Address:
Di Industrial Coatings, Inc.
8230 Meadow Haven D.
Sacramento, CA 95828
Mailing Address:
6426 Crossway Drive, Pico Rivera, CA 90660
Union Status: NonUnion
SIC:
NAICS: 238320/Painting and Wall Covering Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/23/2020
Emphasis:
Case Closed: 08/03/2021
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1540640 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 3 | 4 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $2,363 | $0 | $0 | $630 | $0 | $2,993 |
| Current Penalty | $1,350 | $0 | $0 | $260 | $0 | $1,610 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 1509(C) | 07/24/2020 | 08/05/2020 | $0 | $175 | $0 | 08/20/2020 | O - Administrative Law Judge Order | Citation has been deleted. |
| 2. | 01002 | Other | 1511(B) | 07/24/2020 | 08/05/2020 | $150 | $260 | $0 | 08/20/2020 | O - Administrative Law Judge Order | |
| 3. | 01003 | Other | 3380(F)(1)(A) | 07/24/2020 | 08/05/2020 | $110 | $195 | $0 | 08/20/2020 | O - Administrative Law Judge Order | |
| 4. | 02001 | Serious | 1934(B) | 07/24/2020 | $1,350 | $2,363 | $0 | 08/20/2020 | O - Administrative Law Judge Order |
Investigation Summary
At 1:00 p.m. on January 30, 2020, an employee was cleaning an epoxy spray paint apparatus by spraying flammable thinner thorough it into a plastic bucket that was on a scaffold. The bucket was not grounded or bonded to the scaffold. The thinner vapors caught on fire from static electricity discharge, and the employee sustained burns to the hands. The employee was treated at the hospital and released within a few hours.
Keywords: Burn, Flammable Vapors, Hand, Ignite, Static Electricity, Thinner, Vapor
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1464032.015 | 51 | M | Non Hospitalized injury | Painters, construction and maintenance |
Translate