Inspection Detail
Inspection: 1432002.015 - B.G. Metals, Inc.
Inspection Information - Office: Corpus Christi Area Office
Site Address:
B.G. Metals, Inc.
2502 N.E. Bob Bullock Lp.
Laredo, TX 78045
Mailing Address:
8410 Us Hwy 87 E, San Antonio, TX 78263
Union Status: NonUnion
SIC:
NAICS: 333415/Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/18/2019
Emphasis: L:Constr6
Case Closed: 02/27/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1499660 | Yes | |
| Inspection | 1432790 | Yes | |
| Inspection | 1432771 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $5,398 | $0 | $0 | $0 | $0 | $5,398 |
| Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260416 A01 | 02/10/2020 | $2,500 | $5,398 | $0 | I - Informal Settlement |
Investigation Summary
At 12:00 noon on September 18, 2019, an employee was on a ladder removing AC duct work when he contacted exposed live wires and fell from the ladder. The employee was hospitalized to treat electric shock but recovered.
Keywords: Air Duct, Blunt force, Blunt force trauma, Climbing on Ladder, Contact, Duct, Electric Shock, Electrical Wire, Energized, Fall, Fall From Elevation, HVAC, Stepladder
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1432002.015 | 21 | M | Hospitalized injury | Construction trades, n.e.c. |