Inspection Detail
Inspection: 1407085.015 - Dayton Lease & Pipeline Services, Inc.
Inspection Information - Office: Houston South Area Office
Site Address:
Dayton Lease & Pipeline Services, Inc.
5415 Avenue M
Santa Fe, TX 77510
Mailing Address:
2259 Highway 146, Dayton, TX 77535
Union Status: NonUnion
SIC:
NAICS: 237120/Oil and Gas Pipeline and Related Structures Construction
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/07/2019
Emphasis:
Case Closed: 11/13/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1462862 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $11,934 | $0 | $0 | $0 | $0 | $11,934 |
| Current Penalty | $5,967 | $0 | $0 | $0 | $0 | $5,967 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260651 G01 III | 10/03/2019 | 10/23/2019 | $5,967 | $11,934 | $0 | I - Informal Settlement |
Investigation Summary
At 6:15 p.m. on June 6, 2019, Employees #1 and #2 were repairing a natural gas pipe leak within an excavation. As the employees were performing the hot tap on the pipeline, a valve opened, causing a flash ignition of the gas and ensuing fire. There were several potential ignition sources within the excavation. The two employees were admitted to the hospital with burn to the face and arms.
Keywords: Burn, Construction, Excavation, Explosion, Fire, Flash, Ignition, Natural Gas, Open Valve, Pipeline, Repair
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1407085.015 | 22 | M | Hospitalized injury | Welders and cutters | |
| 2 | 1407085.015 | 27 | M | Hospitalized injury | Pipelayer |
Translate