Inspection Detail
Inspection: 1373157.015 - Poly-America, Lp
Inspection Information - Office: Dallas Area Office
Site Address:
Poly-America, Lp
2000 W. Marshall Dr.
Grand Prairie, TX 75051
Mailing Address:
2000 W. Marshall Dr., Grand Prairie, TX 75051
Union Status: NonUnion
SIC:
NAICS: 325211/Plastics Material and Resin Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/23/2019
Emphasis:
Case Closed: 05/23/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1418165 | Yes |
Investigation Summary
At 4:00 a.m. on January 16, 2019, Employee #1 was using Stamp Machine #890, a table top date code stamper, to record information on cardboard packaging. As the employee removed the plexiglass face from the front of the stamp to move the date, his right finger became caught in the date stamp and was amputated. He was hospitalized for treatment.
Keywords: Amputated, Amputation, Caught In, Finger, Stamper
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1373157.015 | 20 | M | Hospitalized injury | Machine operators, not specified |
Translate