Inspection Detail
Inspection: 1348540.015 - Brand Energy Services
Inspection Information - Office: Miosha Construction Safety & Health Division
Site Address:
Brand Energy Services
1 Quality Dr.
Ecorse, MI 48229
Mailing Address:
12701 Beech Daly, Taylor, MI 48180
Union Status: NonUnion
SIC:
NAICS: 238310/Drywall and Insulation Contractors
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/09/2019
Emphasis: S:Construction
Case Closed: 01/22/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1384848 | Yes |
Investigation Summary
At 9:30 a.m. on September 20, 2018, an employee was operating an overhead monorail crane to hoist racks of insulation blankets. At some point, the employee had his right hand wrapped around the load line while using the pendant controls with his left hand to raise the load. The employee's fingers were caught in the load block sheave with the right pinky finger sustaining an unspecified injury. The employee was hospitalized for surgery to the right pinky finger to pin and stitch the digit.
Keywords: Caught In, Crane, Crane Block, Finger, Hoist, Load Line, Pendant Control, Pinched, Pinned
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1348540.015 | 39 | M | Hospitalized injury | Installers And Repairers |