Inspection Detail
Inspection: 1340868.015 - Crane Pumps & Systems, Inc.
Inspection Information - Office: Cincinnati Area Office
Site Address:
Crane Pumps & Systems, Inc.
420 Third St.
Piqua, OH 45356
Mailing Address:
420 Third St., Piqua, OH 45356
Union Status: NonUnion
SIC:
NAICS: 336312/Gasoline Engine and Engine Parts Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 08/22/2018
Emphasis:
Case Closed: 11/07/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1368907 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19100134 D01 III | 10/12/2018 | $0 | $0 | $0 | Z - Issued | |||
| 2. | 01002 | Other | 19101200 E01 | 10/12/2018 | 11/07/2018 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At 9:00 a.m. on August 22, 2018, Employee #1 was painting a water pump, using an MEK solvent. The employee had a skin reaction and was taken to the hospital. He was admitted to the hospital to monitor for anaphylactic shock.
Keywords: Paint, Paint Solvent, Pump, Skin
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1340868.015 | 41 | M | Hospitalized injury |
Translate