Inspection Detail
Inspection: 1245423.015 - 3d Plastics, Inc.
Inspection Information - Office: Dallas Area Office
Site Address:
3d Plastics, Inc.
1095 E. Commerce Ave.
Gladewater, TX 75647
Mailing Address:
1095 E. Commerce Ave., Gladewater, TX 75647
Union Status: NonUnion
SIC:
NAICS: 326199/All Other Plastics Product Manufacturing
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 06/30/2017
Emphasis:
Case Closed: 12/07/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 1227101 | Yes | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $13,038 | $0 | $0 | $0 | $0 | $13,038 |
| Current Penalty | $7,823 | $0 | $0 | $0 | $0 | $7,823 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19101200 G08 | 11/02/2017 | 11/30/2017 | $3,911 | $6,519 | $0 | I - Informal Settlement | ||
| 2. | 01002A | Serious | 19101200 H01 | 11/02/2017 | 11/30/2017 | $3,911 | $6,519 | $0 | I - Informal Settlement | ||
| 3. | 01002B | Serious | 19101200 H03 I | 11/02/2017 | 11/30/2017 | $0 | $0 | $0 | I - Informal Settlement | ||
| 4. | 01002C | Serious | 19101200 H03 II | 11/02/2017 | 11/30/2017 | $0 | $0 | $0 | I - Informal Settlement | ||
| 5. | 01002D | Serious | 19101200 H03 III | 11/02/2017 | 11/30/2017 | $0 | $0 | $0 | I - Informal Settlement | ||
| 6. | 02001 | Other | 19100134 D01 III | 11/02/2017 | 12/21/2017 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
On June 30, 2017, Employee #1 was repairing a blower machine. As he worked, the employee experienced a headache and began to feel dizzy. The employee passed out and was taken to the emergency room of a nearby hospital, where he was treated for possible exposure to cyanide gas.
Keywords: Chemical, Cyanide, Dizziness, Fainted, Headache
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1245423.015 | 52 | M | Hospitalized injury | Mechanical engineering technicians |
Translate