Inspection Detail
Inspection: 1245219.015 - Venus Spirits Llc
Inspection Information - Office: Fremont District Office
Site Address:
Venus Spirits Llc
427 Swift St. Unit A
Santa Cruz, CA 95060
Mailing Address:
427 Swift St. Unit A, Santa Cruz, CA 95060
Union Status: NonUnion
SIC:
NAICS: 312140/Distilleries
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/08/2017
Emphasis:
Case Closed: 01/03/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1237345 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 4 | 6 | |||
| Current Violations | 2 | 4 | 6 | |||
| Initial Penalty | $21,600 | $0 | $0 | $1,100 | $0 | $22,700 |
| Current Penalty | $11,880 | $0 | $0 | $555 | $0 | $12,435 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 761(B) | 11/08/2017 | $0 | $200 | $0 | I - Informal Settlement | |||
| 2. | 01002 | Other | 467(B) | 11/08/2017 | $185 | $300 | $0 | I - Informal Settlement | |||
| 3. | 01003 | Other | 3308 | 11/08/2017 | 11/17/2017 | $185 | $300 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Other | 6151(C)(1) | 11/08/2017 | $185 | $300 | $0 | I - Informal Settlement | |||
| 5. | 02001 | Serious | 3203(A)(6)(A) | 11/08/2017 | $1,080 | $10,800 | $0 | I - Informal Settlement | |||
| 6. | 03001 | Serious | 3328(G) | 11/08/2017 | $10,800 | $10,800 | $0 | I - Informal Settlement |
Investigation Summary
At 11:16 a.m. on July 5, 2017, an employee was distilling a batch of single malt and brewing a beer while working in the distillery and brewery areas of the store. The employee was operating a 1,000-liter still with the still hatch door closed and heated steam supplied from a boiler in the boiler room. Fluids were leaking from the edge of the hatch and the employee was trying to tighten a replacement clamp on the still's door. The employee suffered second and third degree burns on his right hand, neck, chest, abdomen and back when he was drenched by the escaping heated gases and fluids. The employee was hospitalized.
Keywords: Abdomen, Accidental Discharge, Back, Burn, Chemical, Chest, Compressed Gas, Flowing Material, Hand, Heat, Hot Water, Pressure Vessel, Steam, Struck By
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1245219.015 | 27 | M | Hospitalized injury | Miscelaneous food preparation occupations |
Translate