Inspection Detail
Inspection: 1242237.015 - Rayonier Advanced Materials Inc.
Inspection Information - Office: Jacksonville Area Office
Site Address:
Rayonier Advanced Materials Inc.
10 Gum Street
Fernandina Beach, FL 32035
Mailing Address:
Po Box 2002, Fernandina Beach, FL 32035
Union Status: Union
SIC:
NAICS: 322110/Pulp Mills
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/01/2017
Emphasis: N:Chemnep
Case Closed: 10/06/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1230727 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $12,675 | $0 | $0 | $0 | $0 | $12,675 |
| Current Penalty | $7,605 | $0 | $0 | $0 | $0 | $7,605 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100119 F04 | 08/10/2017 | 09/30/2017 | $7,605 | $12,675 | $0 | I - Informal Settlement |
Investigation Summary
At 12:15 a.m. on June 21, 2017, an employee was unlocking manual valves of a digester. As the valves were loosened, sulfur dioxide leaked from the drain and contacted the employee's face. The employee sustained irritation to his lungs and eyes, which he was hospitalized and received treatment.
Keywords: Accidental Discharge, Chemical, Drain Pipe, Lockout/Tagout, Sulfur Dioxide, Valve
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1242237.015 | 30 | M | Hospitalized injury | Occupation Not Listed |
Translate