Inspection Detail
Inspection: 108177809 - Vantage Manufacturing Services
Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)
Site Address:
Vantage Manufacturing Services
5213 W Lamar
Glendale, AZ 85301
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3672
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 09/26/1990
Emphasis:
Case Closed: 05/06/1991
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360185524 | ||
| Referral | 900137928 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 3 | 5 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $500 | $0 | $0 | $0 | $0 | $500 |
| Current Penalty | $175 | $0 | $0 | $0 | $0 | $175 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19101200 G01 | 11/05/1990 | 12/05/1990 | $250 | $250 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 2. | 01002 | Serious | 19101200 H | 11/05/1990 | 12/05/1990 | $175 | $250 | $0 | I - Informal Settlement | ||
| 3. | 02001 | Other | 19100038 A01 | 11/05/1990 | 11/29/1990 | $0 | $0 | $0 | - | ||
| 4. | 02002 | Other | 19101200 E01 | 11/05/1990 | 12/05/1990 | $0 | $0 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 5. | 02003 | Other | R4130609 A | 11/05/1990 | 11/08/1990 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1 and coworkers were cleaning up a work area. Employee #1 was trying to determine the amount of isopropanol in a 55 gallon drum and opened the container to look inside. As he was tilting it back and forth, his cigarette lighter fell from his pocket into the drum. Employee #1 stood the drum upright and was bending down to retrieve his lighter when the drum exploded. Employee #1 suffered second-degree burns over approximately 70 percent of his body. The container of isopropanol, a class 1A flammable, was not grounded; the lack of grounding may have caused the vapor to ignite and explode.
Keywords: BURN, FLAMMABLE VAPORS, ISOPROPANOL, WORK RULES, CLEANING, DRUM, EXPLOSION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 108177809 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |