Accident Report Detail
Accident Summary Nr: 96318.015 - Employee's sustains crushed right hand during tool change ou
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1239538.015 | 06/14/2017 | 326199 | Rohrer Corporation |
Abstract: At 10:45 a.m. on June 7, 2017, an employee and a coworker were performing a tool change out on a thermoformer machine. Before work, the electrical energy and water supply were secured (lockout/tagout). However, the air supply was not. Nor was a safety jack installed, which the company implemented as part of their lockout/tagout program to provide added protection from crushing injuries during tool change outs. Without knowing that the employee's hands were still inside the machine, the coworker began to manually lower the machine's platen and crushed the employee's right hand.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1239538.015 | 30 | M | Hospitalized injury | Machine operators, not specified |