Accident Report Detail
Accident Summary Nr: 77569.015 - Employee Is Hung When Safety Harness Fails
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1072394.015 | 06/20/2015 | 541330 | Augusta County Service Authority |
Abstract: At 1:30 p.m. on June 21, 2015, an employee was conducting an inspection of a water tower and used a Miller body harness, attached to a Miller Manyard ll - two leg shock absorbing lanyard. The employee was between the 2nd rest platform and the top of the water tower when he fell, between 76 and 113 feet. The employee was wearing fall arrest protection equipment and it was attached to a ladder climbing safety trolley. The connection was made to provide a positioning device. The positioning device requires an additional fall arrest system to be used in conjunction, and the equipment in use was not modified to be sufficient strength to handle a person and tool weight greater than 310 lbs. The force of the fall, weight, and incompatible parts shredded the harness and the employee was found dead hanging with the harness tangled around his neck.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Tower, tank, storage elevator | New project or new addition | 113 | X | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1072394.015 | 47 | M | Fatality | Engineering technicians, n.e.c. | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Other Activities-Installing Ornamental And Archite Fatality Cause: |
Translate