Accident Summary Nr: 200350171 - Two employees injured in aircraft hangar fire
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 300260874 | 11/01/1996 | 4581 | 0 | Raleigh Flying Service |
Abstract: At approximately 5:15 p.m. on October 31, 1996, Employee #1 was removing fuel from one of the seven aircraft located in the maintenance portion of aircraft hanger A. At the same time, Employee #2 was working in the avionics lab located on the second level mezzanine of the hangar. Employee #1 was removing fuel from the plane by letting it flow down into a plastic drum. Fuel vapors were released into the air, where they were ignited, apparently by static electricity. Employee #1 immediately attempted to extinguish the fire. Flames and smoke gathered at the foot of the only stairs from the mezzanine, trapping Employee #2. He was forced to escape through a window and was then transported to the hospital, where he was treated for smoke inhalation and kept overnight for observation. After helping to extinguish the fire, Employee #1 was treated for smoke and dry chemical inhalation, and then released.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300260874 | Hospitalized injury | Other | Aircraft mechanics, excluding engine | ||
| 2 | 300260874 | Non Hospitalized injury | Other | Aircraft engine mechanics |