Accident Report Detail
Accident Summary Nr: 127988.015 - Employee burns hand when vapors caught fire
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1464032.015 | 02/19/2020 | 238320 | Di Industrial Coatings, Inc. |
Abstract: At 1:00 p.m. on January 30, 2020, an employee was cleaning an epoxy spray paint apparatus by spraying flammable thinner thorough it into a plastic bucket that was on a scaffold. The bucket was not grounded or bonded to the scaffold. The thinner vapors caught on fire from static electricity discharge, and the employee sustained burns to the hands. The employee was treated at the hospital and released within a few hours.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Other building | Alteration or rehabilitation | 30 | |||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1464032.015 | 51 | M | Non Hospitalized injury | Painters, construction and maintenance | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Interior painting and decorating Fatality Cause: |