Accident Report Detail
Accident Summary Nr: 119542.015 - Employee amputates finger tip when contacting cutting blade
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1428128.015 | 09/04/2019 | 326112 | Global Plastics Inc |
Abstract: At 9:15 a.m. on August 14, 2019, an employee was working in front of the Trim Press area of a thermoforming machine packaging plastic lids. As the lids exited the machine, the employee reached into the machine, which was not properly guarded. As the employee attempted to remove the lids he was reaching for, his right hand was struck by the cutting blade. The employee amputated the distal tip of his middle finger, requiring medical treatment without hospitalization.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1428128.015 | 18 | M | Non Hospitalized injury | Laborers, except construction |