Effectiveness of the Glove Box for removal of asbestos-containing pipe insulation.

OSHA requirements are set by statute, standards and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This letter constitutes OSHA's interpretation of the requirements discussed. Note that our enforcement guidance may be affected by changes to OSHA rules. Also, from time to time we update our guidance in response to new information. To keep apprised of such developments, you can consult OSHA's website at https://www.osha.gov.

April 4, 1990

Mr. Rick Howell
Universal Insulation, Inc.
Post Office Box 4243
Birmingham, Alabama 35206

Dear Mr. Howell:

This is in response to your letter of March 7, requesting an official opinion as to whether The Glove Box manufactured by Pro/Control Products, Inc., which you propose to use for the removal of asbestos-containing pipe insulation, meets the intent of the occupational safety and health requirements at [29 CFR 1926.1101(g)(5)(iv)].