Violation Detail
Standard Cited: 19100147 C07 I A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1571943.015
Citation: 02002B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/27/2022
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/09/2022
Gravity:
Report ID: 0936400
Contest Date:
Final Order: 06/06/2022
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/06/2022 | $0.00 | 05/09/2022 | Other | |
| Penalty | Z: Issued | 04/27/2022 | $0.00 | 05/09/2022 | Other |
Text For Citation: 02 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. DELINTING CENTRIFUGE: Employees performed lock-out-tag-out and had not been trained on the equipment specific procedures, exposing them to hazards from the unexpected movement of equipment.
Translate