Violation Detail
Standard Cited: 19100217 B07 V A Mechanical power presses.
Inspection Nr: 1409768.015
Citation: 02002
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/29/2019
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 10/17/2019
Gravity:
Report ID: 0112000
Contest Date:
Final Order: 09/24/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/24/2019 | $0.00 | 10/17/2019 | Other | |
| Penalty | Z: Issued | 08/29/2019 | $0.00 | 10/17/2019 | Other |
Text For Citation: 02 Item/Group: 002 Hazard:
29 CFR 1910.217(b)(7)(v)(a): Each two-hand control for single stroke operations on mechanical power press(es) using part revolution clutches was not protected against unintended operation: Press Room: On, or about, June 17, 2019, the run/jog button provided on Press 334, a Walsh partial revolution mechanical power press, were not ringed or otherwise protected against accident contact.
Translate