Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1572089.015
Citation: 02001C
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/23/2022
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity:
Report ID: 0418300
Contest Date:
Final Order: 07/18/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/18/2022 | $0.00 | Other | ||
| Penalty | Z: Issued | 06/23/2022 | $0.00 | Other |
Text For Citation: 02 Item/Group: 001C Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures: (a) On or about January 10, 2022 - New 4x6 machine, employees were exposed to caught-in hazards when the machine specific procedure did not specifically describe the step(s) to verify lockout effectiveness. The procedure said the following: Try equipment for operation and return to neutral or off position.