Violation Detail
Standard Cited: 19100179 G01 V Overhead and gantry cranes.
Inspection Nr: 1715636.015
Citation: 02001
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/15/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity:
Report ID: 0521100
Contest Date:
Final Order: 05/03/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/03/2024 | $0.00 | Other | ||
| Penalty | Z: Issued | 04/15/2024 | $0.00 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.179(g)(1)(v): Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions. On or about December 11, 2023, at an establishment located at 1740 Eisenhower Road in De Pere, Wisconsin, employees of Robinson, Inc. utilized a jib crane with a pendant controller that was not clearly marked for its functions.
Translate