Violation Detail
Standard Cited: 19100217 B07 IV B Mechanical power presses.
Inspection Nr: 1409768.015
Citation: 02001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/29/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/17/2019
Gravity:
Report ID: 0112000
Contest Date:
Final Order: 09/24/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/24/2019 | $0.00 | 10/17/2019 | Other | |
| Penalty | Z: Issued | 08/29/2019 | $0.00 | 10/17/2019 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.217(b)(7)(iv)(b): Being a single control protected against accidental actuation and so located that the worker cannot reach into the point of operation while operating the single control: Press Room: Press 364, a Havir Press Rite partial revolution mechanical power press, was provided with a single jog button that was not ringed or otherwise protected against accidental activation. Abatement Note: The control button appeared to be a re-purposed Top Stop button. The control button should be changed to a standard color and should be properly labeled.