Violation Detail

Standard Cited: 19100119 J02 Process safety management of highly hazardous chemicals.

Inspection Nr: 1565223.015

Citation: 01006

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $11,396.00

Current Penalty: $6,495.72

Issuance Date: 03/28/2022

Nr Instances: 6

Nr Exposed: 6

Abatement Date: 04/21/2022

Gravity: 5

Report ID: 0317300

Contest Date:

Final Order: 07/13/2022

Related Event Code (REC): R

Emphasis:

Substance: 0170


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 07/13/2022 $6,495.72 04/21/2022 Serious  
Penalty Z: Issued 03/28/2022 $11,396.00 04/21/2022 Serious  

Text For Citation: 01 Item/Group: 006 Hazard:

29 CFR 1910.119(j)(2): The employer did not establish or implement written procedures to maintain the on-going integrity of process equipment: a) House Engine Room: On or about 10/1/2021, the employer did not implement their written procedures to maintain the on-going integrity of process titled, "Replacement of Piping or Fittings", to clean corroded metal surfaces, and then apply corrosion inhibitor along the C-2 HSS pipe run identified as having visible corrosion, allowing for accelerated pipe corrosion, potentially resulting in pipe failure and subsequent employee exposure to an ammonia inhalation hazard which can result in serious illness or death. b) House Engine Room: On or about 10/1/2021, the employer did not implement their written procedures to maintain the on-going integrity of process titled, "Replacement of Piping or Fittings", to clean corroded metal surfaces, and then apply corrosion inhibitor along the C-7 LSS pipe run identified as having visible corrosion and insulation removed, allowing for accelerated pipe corrosion, potentially resulting in pipe failure and subsequent employee exposure to an ammonia inhalation hazard which can result in serious illness or death. c) House Engine Room: On or about 10/1/2021, the employer did not implement their written procedures to maintain the on-going integrity of process titled, "Replacement of Piping or Fittings", to clean corroded metal surfaces, and then apply corrosion inhibitor along the P-1 Recirculator E L TRS pumped liquid piping identified as having visible corrosion, allowing for accelerated pipe corrosion, potentially resulting in pipe failure and subsequent employee exposure to an ammonia inhalation hazard which can result in serious illness or death. d) FRIGO Engine Room: On or about 10/1/2021, the employer did not implement their written procedures to maintain the on-going integrity of process titled, "Replacement of Piping or Fittings", to clean corroded metal surfaces, and then apply corrosion inhibitor and replace the insulation along the Compressor 11-FC1 LSS piping identified as having damaged insulation, allowing for accelerated pipe corrosion, potentially resulting in pipe failure and subsequent employee exposure to an ammonia inhalation hazard which can result in serious illness or death. e) FRIGO Engine Room: On or about 10/1/2021, the employer did not implement their written procedures to maintain the on-going integrity of process titled, "Replacement of Piping or Fittings", to clean corroded metal surfaces, and then apply corrosion inhibitor along the Compressor 11-FC1 HSD piping identified as having slight visible corrosion, allowing for accelerated pipe corrosion, potentially resulting in pipe failure and subsequent employee exposure to an ammonia inhalation hazard which can result in serious illness or death. f) FRIGO Engine Room: On or about 10/1/2021, the employer did not implement their written procedures to maintain the on-going integrity of process titled, "Replacement of Piping or Fittings", to clean corroded metal surfaces, and then apply corrosion inhibitor along the Compressor 11-FC2 HSS piping identified as having insulation vapor barrier leaks, allowing for accelerated pipe corrosion, potentially resulting in pipe failure and subsequent employee exposure to an ammonia inhalation hazard which can result in serious illness or death. Pursuant to 29 CFR 1903.19, the employer must submit abatement certification, required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.