Powered by GoogleTranslate

Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 310988712

Citation: 01005

Citation Type: Serious

Abatement Status: X

Initial Penalty: $5,000.00

Current Penalty: $5,000.00

Issuance Date: 07/25/2008

Nr Instances: 9

Nr Exposed: 40

Abatement Date: 08/04/2008

Gravity: 10

Report ID: 0418400

Contest Date: 07/25/2008

Final Order: 07/07/2010

Related Event Code (REC):

Emphasis:

Substance: E200


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty F: Formal Settlement 07/07/2010 $5,000.00 08/04/2008 Serious  
Penalty Z: Issued 07/25/2008 $5,000.00 08/04/2008 Serious  

Text For Citation: 01 Item/Group: 005 Hazard: EXPLOSION

P.L. 91-596 Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer does not furnish employment and a place of employment which are free from recognized hazards that are causing or likely to cause death or serious physical harm to employees in that employees are exposed to the hazard(s) of explosion and fire: a.Top of Silos 1, 2, & 3 (9th floor) and Bottom of Silo (tunnel) - On or about 02/07/2008, bulk material steel conveyor belts on the top and bottom of the silos that convey granulated sugar were not equipped with bearing temperature, belt alignment, and vibration detection monitors at the head and tail pulleys to shut down equipment and/or notify the operator before the initiation of a fire and/or explosion, exposing employees to explosion and fire hazards. b.South Packing House & Bosch Packing House - On or about 02/07/2008, inside legs (bucket elevators) used to convey granulated sugar were not equipped with bearing temperature, belt alignment, and vibration detection monitors at the head and tail pulleys to shut down equipment and/or notify the operator before the initiation of a fire and/or explosion, exposing employees to explosion and fire hazards. One feasible means of abatement is to install bearing temperature, belt alignment, and vibration detection monitors at the head and tail pulleys of all steel belt conveyors and inside legs (bucket elevators), as referenced in National Fire Protection Association (NFPA) 61, 2008 & 2002, Chapter 7.3. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days, the employer must submit an abatement plan describing the actions it is taking to prevent the hazards described in instances a and b, above.ces

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.