Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1443413.015
Citation: 01004C
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/09/2020
Nr Instances: 4
Nr Exposed: 8
Abatement Date: 06/30/2020
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 04/02/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/02/2020 | $0.00 | 06/30/2020 | Serious | |
| Penalty | Z: Issued | 03/09/2020 | $0.00 | 04/06/2020 | Serious |
Text For Citation: 01 Item/Group: 004C Hazard:
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section. (a) The belt transferring power from the 52 inch head saw drive motor was not fully enclosed by a guard exposing employees to ingoing nip points and caught in hazards. (b) The belt transferring power on the north side of the edger was not guarded exposing employees to ingoing nip points and caught-in hazards. (c) The belt transferring power on the south side of the edger was guarded with a wooden box that was easily removed exposing employees to ingoing nip points and caught-in hazards. (d) The belt transferring power on the enclosed dust collector on the north side of the building was not guarded exposing employees to ingoing nip points and caught-in hazards.