Violation Detail
Standard Cited: 19170151 B07 Machine guarding.
Inspection Nr: 1638583.015
Citation: 01004
Citation Type: Other
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $4,465.00
Current Penalty: $3,000.00
Issuance Date: 06/07/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 09/29/2023
Gravity: 5
Report ID: 0111400
Contest Date: 06/30/2023
Final Order: 10/30/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 10/30/2023 | $3,000.00 | 09/29/2023 | Other | |
| Penalty | C: Contested | 06/30/2023 | $4,465.00 | 06/15/2023 | Serious | |
| Penalty | Z: Issued | 06/07/2023 | $4,465.00 | 06/15/2023 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1917.151(b)(7):The power supply to machines was not turned off, locked out and tagged out during repair, adjustment, or servicing. Location; Kocks # 2 crane The employer failed to ensure that the crane was locked out prior to servicing.