Violation Detail
Standard Cited: 19100303 E01 II General.
Inspection Nr: 1634827.015
Citation: 01004
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,278.00
Current Penalty: $10,547.00
Issuance Date: 05/12/2023
Nr Instances: 1
Nr Exposed: 70
Abatement Date: 05/24/2023
Gravity: 5
Report ID: 0626300
Contest Date:
Final Order: 05/31/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/31/2023 | $10,547.00 | 05/24/2023 | Serious | |
| Penalty | Z: Issued | 05/12/2023 | $12,278.00 | 05/24/2023 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.303(e)(1)(ii): Electric equipment was used without markings giving voltage, current, wattage, or other ratings as necessary: On or about November 15, 2022, and at times prior thereto; in the Assembly area, where the electrical panel was used to power the Disconnect to the Reamer KSB 50C and other equipment was not markings giving voltage, current, or other ratings as necessary, exposing employees to electrocution, electrical shock and burns hazards.