Violation Detail
Standard Cited: 19100146 D06 Permit-required confined spaces
This violation item has been deleted.
Inspection Nr: 1259741.015
Citation: 01004
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,934.00
Current Penalty: $0.00
Issuance Date: 02/27/2018
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 10
Report ID: 0317500
Contest Date: 03/20/2018
Final Order: 09/13/2019
Related Event Code (REC): A
Emphasis:
Substance: 1480
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 09/13/2019 | $0.00 | Serious | ||
| Penalty | C: Contested | 04/20/2018 | $12,934.00 | Serious | ||
| Penalty | Z: Issued | 02/27/2018 | $12,934.00 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.146(d)(6): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not provide at least one attendant outside the permit space into which entry was authorized for the duration of entry operations: a) In the North Division Vault of the North LDS Pond, on or about August 29, 2017 - The employer failed to provide an attendant outside the vault while employees entered the vault to remove an elbow from a 24-inch pipe line which introduced a water engulfment hazard, hydrogen sulfide atmospheric hazard, and hazards associated with oxygen fuel gas torch use into the space.