Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1322895.015
Citation: 01003A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,654.00
Current Penalty: $4,690.00
Issuance Date: 10/24/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 11/26/2018
Gravity: 5
Report ID: 0524500
Contest Date:
Final Order: 11/08/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/08/2018 | $4,690.00 | 11/26/2018 | Serious | |
| Penalty | Z: Issued | 10/24/2018 | $5,654.00 | 11/26/2018 | Serious |
Text For Citation: 01 Item/Group: 003A Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this sec: On or about June 13, 2018, employees conducting maintenance activities entered the extraction cooling tower to remove, inspect and clean the nozzles. These activities required the control of hazardous energy of equipment such as fans and pumps and the employer had not developed an adequate energy control program that was specific to the work being done in the facility or the equipment being serviced or maintained in the facility.