Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1568165.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,801.00
Current Penalty: $2,900.50
Issuance Date: 03/04/2022
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 03/23/2022
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 03/24/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/24/2022 | $2,900.50 | 03/23/2022 | Serious | |
| Penalty | Z: Issued | 03/04/2022 | $5,801.00 | 03/23/2022 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d):Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6): a. On or before December 1, 2021, employees were exposed to machine hazards associated with moving parts during servicing and maintenance of the #2 Extruder Machine. The employer failed to implement energy control application steps as the energy was not isolated from the machine to perform the servicing work [per the 1910.147(d)(3) requirements]. As a result, the remaining applicable energy control LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.