Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1394610.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,293.00
Current Penalty: $3,646.50
Issuance Date: 08/28/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 09/09/2019
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 09/18/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/18/2019 | $3,646.50 | 09/09/2019 | Serious | |
| Penalty | Z: Issued | 08/28/2019 | $7,293.00 | 09/09/2019 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): A) Mid-States Packaging, Inc., located at 12163 State Route 274, Lewistown, OH 43333: On or about April 15, 2019, the employer did not ensure that all the steps outlined in 29 CFR 1910.147(d), required for the control of the hazardous energy sources, were performed. Employees did not deenergize the 100 Ton Freeman Schwabe Automatic Press (Model # BP100-5979H; Serial # FHH1009) prior to conducting activities such as, but not limited to, attempting to find air leaks. Employees were exposed to the hazards that could result in personal injuries while all hazardous energy sources were not controlled prior to performing the tasks.