Violation Detail
Standard Cited: 19260850 A Preparatory operations.
Inspection Nr: 1389471.015
Citation: 01003
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,525.00
Current Penalty: $5,526.66
Issuance Date: 09/24/2019
Nr Instances: 1
Nr Exposed: 18
Abatement Date: 10/02/2019
Gravity: 5
Report ID: 0317000
Contest Date:
Final Order: 10/07/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/07/2019 | $5,526.66 | 10/02/2019 | Serious | |
| Penalty | Z: Issued | 09/24/2019 | $8,525.00 | 10/02/2019 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.850(a): Prior to permitting employees to start demolition operations, an engineering survey was not made by a competent person of the structure to determine the condition of the framing, floors, and walls, and possibility of unplanned collapse of any portion of the structure, including adjacent structures where employees may be exposed. The employer did not have in writing evidence that such a survey was performed. a) Jobsite: 11601 Roosevelt Blvd, Philadelphia - The employer did not have a competent person complete an engineering survey on the approximate 400k square foot single story commercial building prior to permitting employees to conduct demolition operations, thus exposing employees to hazards such as unsafe framing, floors, and walls, and unplanned collapses. Noted on or about 3/29/19.