Standard Cited: 19100106 E06 I Flammable liquids.
Inspection Nr: 1364700.015
Citation: 01003
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $9,282.00
Current Penalty: $5,846.00
Issuance Date: 04/25/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0214200
Contest Date:
Final Order: 05/07/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/07/2019 | $5,846.00 | Serious | ||
| Penalty | Z: Issued | 04/25/2019 | $9,282.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors: Location: 401 South St Newark, NJ 07105 - Yard/Staging Area On or about 12/3/18 an employee sustained serious injury when a steel drum exploded as he used a portable Dewalt grinder to open the drum and abstract colors. Sparks produced during grinding operations ignited flammable/combustible liquid residue in the drum resulting in fire/explosion.