Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1472197.015
Citation: 01002D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/05/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/31/2020
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 08/28/2020
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/28/2020 | $0.00 | 12/31/2020 | Serious | |
| Penalty | Z: Issued | 08/05/2020 | $0.00 | 09/02/2020 | Serious |
Text For Citation: 01 Item/Group: 002D Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about April 8, 2020, employees were exposed to machine hazards associated with moving parts when they engaged in cleaning activities on the Industrial Stainless, Inc. hopper in connection with the PacTec (Model: PT-4/6S, S/N: 2201). The informal procedure used by employees for rinsing and cleaning the hopper did not utilize an energy isolating device. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.