Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1546175.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/08/2021
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 12/30/2021
Gravity: 1
Report ID: 0316700
Contest Date:
Final Order: 11/18/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/18/2021 | $0.00 | 12/30/2021 | Serious | |
| Penalty | Z: Issued | 10/08/2021 | $0.00 | 11/29/2021 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(7)(i)(B): Each affected employee was not instructed in the purpose and use of the energy control procedure. a) Rigid Ply Rafters- The employer did not ensure affected employees who conduct work in area where service and maintenance operations are conducted were instructed on the purpose and use the of the energy control procedures, on or about April 16, 2021. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Translate